Page 8
The BoilerMate SP is a hot water only thermal store. It is intended to be used in
conjunction with a sealed primary system. This is generally expected to be a system
boiler; however this product can also be in a central plant or district heating system.
Please check the table opposite for the maximum pressures.
Heat energy is input into the store via the store plate heat exchanger, store pump and
associated pipework which is fitted to the product. The installer must supply all the
other necessary components to feed the boiler side of the store plate heat exchanger.
Domestic hot water is generated instantaneously
by the BoilerMate domestic hot water assembly.
It is supplied to the taps at mains pressure and
at 55°C. See the domestic hot water installation
section for details.
Please see the drawing below for connections,
location size and type.
Standard Equipment
The standard configuration of the BoilerMate
SP is shown opposite. It is supplied with the
following factory fitted equipment:-
1 90 degree elbow - vent (22mm
compression)
2 Domestic hot water PCB box
3 Compression elbow (22mm)
4 Straight isolator (22mm to FF3/4”)
5 Bent isolator - CV fitted (22mm to FF3/4”
6 Domestic hot water pump (PWM2)
7 Store PHE (insulated) 24 plate
8 Boiler flow (22mm compression)
9 Domestic hot water PHE (insulated) 24
plate
10 Flow sensor and hot water sensor
11 Boiler return (22mm compression)
12 Store pump
13 Cold water sensor
14 Cold feed (22mm compression)
15 Inline strainer/flow regulator (22mm
compression) mains cold water in
16 Drain valve
17 Bent isolator (22mm to FF3/4”)
18 Store control thermostat
19 3kW immersion heater (backup)
20 Bent isolator - CV fitted (22mm to FF3/4”)
21 Hot water outlet (22mm compression)
Optional Equipment Kits For BMST-SP
1. Sealed primary header tank kit (BCK002)
2. Switch Back up conversion 6kW to 3kW
kit (BCK003)
3. Timer kit (BCK004)
4. Sealed system ROBOKIT (BCK005)
5. Second Heating Zone kit (BCK006)
6. Pump over run kit (BCK007)
7. DHW scale prevention kit (BCK008)
1
3
4
6
9
10
13
21
14
15
2
5
7
8
11
12
16
17
18
19
20
SELECTION
BOILERMATE SP
Summary of Contents for BOILERMATE OV PP