The Buffer store is insulated to a very high standard using high density
HCFC free foam cased in a steel shell and has an ozone depletion potential
(ODP) of zero and a global warming potential (GWP) of 2.
The specification of the models are shown in the following tables.
DESIGN
TECHNICAL DATA
Heating Flow
Heat Pump Return
Heating Return
Heat Pump Flow
Sensor Pocket
Sensor Pocket
StainlessLite Plus Direct Buffer Store Technical Specification
Description
90D
120D
210D
300D
400D
Product stock code
PLUDR090B
PLUDR120B
PLUDR210B
PLUDR300B
PLUDR400B
Energy efficiency class
A
B
B
C
C
Heat loss
watts
32
39
62
86
87
kWh/24h
0.77
0.94
1.49
2.06
2.09
Capacity
litres
91
119
208
287
393
Height
mm
764
931
1494
1990
2030
Diameter
mm
550
550
550
550
630
Weight (empty)
kg
17
20
30
39
51
Weight (full)
kg
108
139
238
326
451
Maximum working pressure - cylinder
bar
3.5
3.5
3.5
3.5
3.5
Maximum working pressure - space heating
bar
3.5
3.5
3.5
3.5
3.5
Central heating flow connection
mm
28
28
28
28
28
Central heating return connection
mm
28
28
28
28
28
Heat pump flow connection
mm
28
28
28
28
28
Heat pump return connection
mm
28
28
28
28
28
Central heating flow tapping height
mm
798
966
1530
2025
2030
Central heating return tapping height
mm
225
225
225
225
214
Heat pump flow tapping height
mm
504
672
1235
1731
1805
Heat pump return tapping height
mm
325
325
325
325
314
Thermostatic pocket size - Bottom
mm
22
22
22
22
22
Thermostatic pocket size - Top
mm
22
22
22
22
22
Thermostatic pocket height - Bottom
mm
275
275
447
586
621
Thermostatic pocket height - Top
mm
458
567
933
1255
1201
Summary of Contents for STAINLESSLITE PLUS