2.2 INSTALLATION
2.0 INSTALLATION
Make the connections as shown opposite on
the terminal strip provided.
The appliance is provided with a link
between terminals 9 and 11 on the terminal
strip. This must be removed if a room
thermostat is fitted see opposite.
No Clock Models
• If a remote clock is not being provided links
will be required between 21/22 and 22/23.
• If a single remote clock is being provided
a single link will be required between 21/22
to allow the appliance to provide hot water
24hrs/day.
• If a two channel clock is being provided
no links will be required. (A two channel
clock is normally only required to eliminate
noise caused by the boiler firing during the
night).
• Wire the connections from the clock as
shown opposite.
Clamp the cables in the grips provided below
the terminal strip and ensure all cables are
routed to avoid hot surfaces.
Note: The appliance is provided with a 4.0mm
earth cable from an earthing strap on the
heating system bypass pipe to the earth stud
on the wiring panel.
Electrical Connection - Standard Appliance
The SysteMate 2000 is pre-wired to a 12 way
terminal strip from the A.C.B. and plumbers are
well able to complete the electrical installation
provided they adhere strictly to the IEE
Requirements for Electrical Installations BS
7671. A schematic arrangement of the wiring
is shown on page 24.
All the terminals are suitably labelled.
Note: Do not attempt the electrical work
unless you are competent to carry it out to the
above standards.
Before commencing check that the power
source is in accordance with section 1.2 Site
Requirements and ensure that it is isolated.
Run the external wiring through the service
slot provided in the base of the appliance.
It is recommended that the 3 core input cable
from the isolator to the appliance is not less
than 1.5mm
2
PVC grade to BS 6500.
L
E
N
L
E
N
SL
L
E
N
SL
ROOMSTAT
BOILER
MAINS
1
2
3
4
5
6
7
8
9
10
11
12
INCOMING
POWER
SUPPLIES
230V 50 Hz
3 amp
OUTGOING
SUPPLY
TO BOILER
OUTGOING
SUPPLY TO
ROOMSTAT
(IF FITTED)
LINK
FROST
PROTECTION
Wiring guide from Clock to ACB
Neutral - Terminal 20
Permanent Live (to clock) - Terminal 21
Hot Water Channel Switched Live (from clock) - Terminal 22
(only required with 2 channel clock)
Heating Channel Switched Live (from clock) - Terminal 23
Summary of Contents for SysteMate 125
Page 8: ...Supplied By www heating spares co Tel 0161 620 6677 Page 8 1 0 DESIGN 1 2 TECHNICAL DATA ...
Page 31: ...Supplied By www heating spares co Tel 0161 620 6677 Page 31 SYSTEMATE 2000 3 0 SERVICING ...
Page 40: ...Supplied By www heating spares co Tel 0161 620 6677 Page 40 ...
Page 41: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 42: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 43: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 44: ...Supplied By www heating spares co Tel 0161 620 6677 ...