SERVICING AND MAINTENANCE
SERVICING AND MAINTENANCE
FAULT FINDING
FAULT FINDING
UNSATISFACTORY
HOT WATER
PERFORMANCE
Is the power supply
to the PHE controller
switched on
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
Switch it on
Follow the
fault finding
chart
Is the boiler
thermostat
set to max?
Is the model
suitable for the
hot water
requirement?
Change for
correct
model
Change boiler
for larger
model
Adjust boiler
thermostat to
maximum
Is the Torrent
thermostat set
too low?
Is the boiler
output at least
10% more than the
rad. loading?
Does the boiler
flow reach
temperature?
Is the boiler
thermostat
adjustable?
Correct Torrent
thermostat setting
(set to 75ºC)
Report to the
boiler
manufacturer
Adjust to
maximum
Descaling
of the PHE
required
Is heat
exchanger
scaled up
internally?
(Indicated by
reduction of
flow rate)
Alter pipe
sizes
Does the temp
rise across the
boiler exceed 11°C
Increase boiler
pump setting
H.W. flow too
great?
Is the temp.
rise too high?
Regulate flow
from outlet fitting
(tap)
Is the circuit
correctly sized?
Fit an air vent
Is the temp.
rise now
satisfactory?
Investigate for
blockage
Is air
trapped in
the primary
circuit?
Test Equipment
The initial assumption in this procedure is that the plumbing and water supply is
working effectively. If in doubt please confirm and refer to the end of this section for
advice on specific components.
A multi meter, a weir gauge and a thermometer will be required to confirm that all
the components are working effectively.
The PWM controller PCB manufacturer suggests “Fluke 87 TRUE RMS Multi meter” as
a suitable product. This will be able to measure;
- the frequency output from the Board to the pump
- the Duty cycle % output from the Board to the pump
Connection numbering
For reference the connections to the PCB are numbered below for
Logical sequence;
- check electrical connections fault finding section on page 34 first to ensure your
own safety. This section will potentially identify any short circuited components
and/or wiring faults that need to be rectified before continuing to work on the
appliance.
- check that the correct information is being supplied to the board. This section will
identify if any sensors are faulty or out of tolerance. These will need to be replaced
before continuing
- check that the overheat link is present (J7 see page 37)
- check that the outputs to the board are being generated. If at this stage the board
does not provide the correct outputs then potentially the board should be replaced
- check the pump electrical circuit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
1
2
3
4
1
2
3
4
5
6
7
8
1
2
1
2
3
4
5
6
7
8
9
1
10
2 3
4 5 6
J18
J20
J19
J3
J7
J8
J1