© Dimplex Boilers 20

08

Dimplex 18 OV
Dimplex 32 OV

Open Vented Condensing Boilers

User’s Operating
Instructions

These instructions should be left with the user

Part No: 751288 - Issue 3 - 07/07/10

© Dimplex Boilers 2008

Glen Dimplex Boilers is continually improving its products and therefore 

reserve the right to change product specifications without prior notice. 

Errors & omissions excepted.

Glen Dimplex Boilers

Stoney Lane

Prescot

Merseyside. L35 2XW

For all telephone enquiries call:

0844 371 2222

website:

www.glendimplexboilers.com

Part of the Glen Dimplex Group

S A L E S   A N D   S E R V I C E   H E L P L I N E :   0 8 4 4   3 7 1   1 1 1 1

Summary of Contents for Dimplex 18 OV

Page 1: ... Dimplex Boilers 2008 Dimplex 18 OV Dimplex 32 OV Open Vented Condensing Boilers User s Operating Instructions These instructions should be left with the user ...

Page 2: ... 4 0 Error Codes 6 5 0 Additional Information 7 Natural Gas Dimplex 18 OV Gas Council Appliance No 41 149 04 Dimplex 32 OV Gas Council Appliance No 41 149 03 2 Dimplex Boilers 2008 GAS COUNCIL NUMBERS Control Panel Fig 1 Read these instructions carefully before trying to operate the appliance ...

Page 3: ...n the CH temperature Control knob to the midpoint between the minimum and maximum setting The display changes from O to h 3 Ensure Programmer and room thermostat if fitted are calling for heat 4 The display changes to H When the boiler has lit a small dot will also appear in the bottom right corner of the display 5 If the burner fails to light the fan will stop Initially this may be due to air in ...

Page 4: ... the CH temperature control knob ON Is the timer on and calling for heat Is the room thermostat set high enough Reset the boiler see Section 5 7 If the boiler does not reset contact your installer or service engineer Yes No No No No No Yes Yes Yes Consult gas supplier Turn the knob clockwise Ensure the timer is set for central heating on see your timerinstructions Turn the room thermostat to maxim...

Page 5: ... mains supply must facilitate complete isolation of the appliance Either a 3A fused three pin plug and unswitched shuttered socket outlet or a 3A fused double pole switch having a 3mm contact separation in both poles serving only the boiler and its external controls may be used 3 3 ELECTRICAL SUPPLY 3 4 CLEARANCES AND VENTILATION 5mm Min 372mm 5mm Min 580mm 200mm 200mm 285mm Wall 450mm Min For Ser...

Page 6: ...heck external pump Check PCB PCB connectors ERROR CODE DESCRIPTION REASON ACTION RESET POSSIBLE 5 Defective sensor or Defective flow return or flue Check wiring to sensors thermal fuse blown sensor or heat exchanger Check PCB X6 X8 connectors reached maximum safe Check flow return and flue sensors working temperature CHECK THERMAL FUSE IS OPEN CIRCUIT IF SO REPLACE HEAT EXCHANGER SEE 10 8 6 Defect...

Page 7: ... must be carried out by a competent person such as British Gas or other CORGI Registered personnel 5 5 PLUMING FROM TERMINAL Like all condensing boilers this appliance will produce a plume of condensation from the flue terminal This is due to the high efficiency and hence low flue gas temperature of the boiler It is normal and not a fault indication The boiler is fitted with a condensate trap The ...

Page 8: ...rve the right to change product specifications without prior notice Errors omissions excepted Glen Dimplex Boilers Stoney Lane Prescot Merseyside L35 2XW For all telephone enquiries call 0844 371 2222 website www glendimplexboilers com Part of the Glen Dimplex Group S A L E S A N D S E RV I CE H E L P L I N E 0 8 4 4 3 7 1 1 1 1 1 ...