background image

 

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

 

Glen Convector Heaters
Models : EC532 and EC533

Installation and Operating Instructions

Dimensions

(millimetres)

Model

(

s

)

Specification

EC532

2.0kw  Heat Switch

EC533

2.0kw  Thermostat

Fig. 1

General

The heater may be used free standing on feet or wall mounted on
brackets. The necessary feet, screws and wall brackets are provided.
The heater should only be operated when in the upright position as
shown in Fig. 1 above.

To fit feet

Remove the two foot fixing screws from the transit position at each end
of the heater base (one screw holds the 3 wall brackets in place - see ‘a’
in Fig. 2). Retain the wall brackets for possible future use.
Locate the feet by aligning the pins in the feet with the holes in the
heater base. Secure each foot with the screws supplied (see ‘c’ in Fig.
2).

ON NO ACCOUNT SHOULD THE HEATER BE USED FREE STANDING
WITHOUT THE FEET FITTED.

Fig. 2

IMPORTANT SAFETY ADVICE

WARNING –THIS APPLIANCE MUST NOT BE USED IN A

BATHROOM

WARNING  - DO NOT USE THIS HEATER IN THE IMMEDIATE

SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING

POOL.

WARNING – THIS HEATER MUST NOT BE LOCATED

IMMEDIATELY BELOW A FIXED SOCKET OUTLET.

DO NOT USE THE HEATER UNTIL THE FEET OR WALL

BRACKETS ARE FITTED CORRECTLY.

FOLLOW these instructions carefully.

NEVER cover or obstruct in any way the heat outlet slots at

the top of the heater or the air inlet slots in the base of the

heater.

The heater carries a warning ‘DO NOT COVER’ to alert the

user to the risk of fire that exists if the heater is accidentally

covered.

If young children, the aged or infirm are likely to be left in the

vicinity of the heater, we advise that adequate precautions

should be taken.-

We recommend that a guard be fitted to ensure contact with

the heater is avoided and objects cannot be inserted into the

product.

If the mains lead is damaged, it must be replaced by the

manufacturer or its service agent or a similarly qualified

person in order to avoid a hazard.

For further information, please contact our guard supplier

direct on Tel. No. 01603 667957, or in case of difficulty or for

further advice contact the Customer Helpline.

Electrical connection

WARNING – THIS APPLIANCE MUST BE EARTHED

This heater must be used on an ~ supply only and the voltage marked
on the heater must correspond to the supply voltage. This heater is
fitted with a rewirable plug incorporating a 13 amp fuse. In the event of
replacing the fuse in the plug supplied, a 13 amp fuse approved by
ASTA to BS 1362 must be used. If any other type of plug is used, a 15
amp fuse must be fitted in the plug, the adaptor, or at the distribution
board.
IMPORTANT : If the plug is not suitable for your socket, the 13 amp
plug should be removed. Before wiring the appropriate plug, please note
that the wires in this mains lead are coloured in accordance with the
following code :

GREEN AND YELLOW :

EARTH

BLUE :

NEUTRAL

BROWN :

LIVE

Connect the 

GREEN AND YELLOW

 wire to the terminal marked ‘

E

’ or

by the earth symbol  

 ,

 

or coloured 

GREEN

 or 

GREEN AND YELLOW

.

Connect the 

BROWN

 wire to the terminal marked ‘

L

’ or coloured 

RED

.

Connect the 

BLUE

 wire to the terminal marked ‘

N

’ or coloured 

BLACK

.

INGCUKEC53     Issue 1

425

MIN

545

230
MIN

Floor Mtd.

365

MIN

230

MIN

450

Wall Mtd.

shelf

230

Positioning the heater

Always ensure that the heater is stood on a firm, level base near to, but
not directly beneath, a suitable mains supply socket.
Ensure that curtains and furniture are not positioned close to the chosen
position, as this would create a potential fire hazard.
We recommend that the heater should be wall-mounted in rooms where
children may be left unattended.
See also ‘Important Safety Advice’

 