background image

C

ABLEMASTER

W

IRING

I

NSTRUCTIONS

(see wiring diagram, page 15)

Some wiring instructions are basic to the wiring of the 

Cablemaster 

regardless what model (CM-4, CM-7

or CM-8) you purchased. 

F

IRST

, all wiring should be done in accordance with the instructions contained in the National Electrical Code. If there

is any uncertainty as to the proper methods of wiring, a qualified and competent electrician should do the wiring. 

S

ECOND

, overcurrent protection (fuse or circuit breaker) must be provided in the power supply to the 

Cablemaster.

On

12v DC systems, a 20 amp fuse or circuit breaker should be used; on 24v DC systems, a 15 amp fuse or circuit breaker

is required. In addition to providing electrical “overload” protection, a separate breaker for the 

Cablemaster

allows the unit

to be turned “off” thus preventing the unauthorized use

of  the  unit  when  left  unattended. 

This  is  especially

IMPORTANT

if the switch is located where it can easily be

actuated by children.

Follow the instructions below for the specific model

you purchased: 

T

HE

CM-4 

POWER UNIT

is  wired  through  a  barrier

strip. 

All electrical connections to the barrier strip have

been completed at the factory to make for easy instal-

lation. All that is required by the installer is to attach the

battery to the appropriate terminals on the barrier strip.

Using 12 gauge, stranded wire, the positive DC power supply is connected to the #5 terminal on the barrier strip and

the negative to the #6 terminal (see drawing right). Be sure to observe proper polarity when connecting the DC input wires.

Both the limit switches are designed to automatically stop the motor when the cable has reached its’ limit of travel. The

in-limit switch is located in the hawse pipe gasket ring and is covered by a neoprene cover to shield it from moisture. The

in-limit swithch, which is connected to the #1 and #2 terminals on the barrier strip, is activated when the plug cover touch-

es the switch.

The out-limit switch, which is connected to the #3 and #4 terminals of the barrier strip, is located in the guide roller

assembly mounted on the lower side of the power unit and is activated by a nylon safety collar secured near the terminal

end of the shore power cable. The collar, which acts as a positive mechanical “stop” as well as a means to activate the

out-limit switches, should be fitted around the shore power cable at a point that allows adequate slack in the cable for

unstrained  AC  electrical  connections.  If  the  shore  power  cable  is  being

directed through the vertical pipe extension, it is necessary to relocate the

guide  roller  assembly  with  the  out-limit  switch  from  the  power  unit  to  the

lower end of the vertical pipe and to reconnect the out-limit switch using the

appropriate lengths of wire. 

(NOTE: Failure to install the nylon safety collar and rewire the out-limit

switch can result in damage to the shore power cable’s electrical con-

nection.)

The six conductor cable for the power switch is numerically marked to cor-

respond with the numbers on the barrier strip. For convenience and ease of

operation, the power switch should be mounted near the hawse pipe or in the appropriate hole with the optional bezel. In

each case, the power switch must be protected by the neoprene cover to prevent the intrusion of moisture.

D

1

2

3

4

5

6

IN-LIMIT

SWITCH

OUT-LIMIT

SWITCH

BATTERY POSITIVE (+)
BATTERY NEGATIVE (-)

GREEN
YELLOW
BROWN
BLUE

BLACK

RED

CIRCUIT BREAKER SPECS. :
CM4 - 12 VOLT  10 AMP BREAKER    4 - 5 RUNNING AMPS

BLACK

WHITE

DC MOTOR

BROWN

OUT

GREEN

POWER

SWITCH

IN

BLACK

RED

YELLOW

BLUE

T

YPICAL

CM-4 B

ARRIER

S

TRIP

W

IRING

6

Installer needs only to attach 

battery power to barrier strip

W

IRING THE

CM-4 C

ABLEMASTER

MO

TOR

25-5/8" 

(651

 mm

)

M

in

imum

 di

sta
nc

e t

o

ce

n

te

r of

 st

or

age
 spac

e

14-1/8"

(359 mm)

13"

(33
0 m

m

)

6"

  (152 mm)

7"

 (178 

mm)

28-1/4"

(718

 mm)

12-3/4"

(324 mm)

8-1/2"

 (216 

mm)

18"
 (457 mm)

5-1/2"

 (140 

mm)

8-3/8"

(213

 mm)

4"

(102 mm)

SPECIFI

CA
TIONS

Vo

ltage:

   

 12v DC (24v

 DC a

vailable).

C

ur

re

n

t:  

   7 - 11 A

mps under load

W

ei

gh
t:  

    40 lbs

. (P

o

we
r unit)

            12

 lbs
. (H

aw
se

 pip
e)

Ca

b

le

 siz

e:  

 up t

o 2 gauge - 5 c

onduc

tor

, 100amp

                  

  A

djustable

 (1.325"

 - 1.650" dia.)

Le

n

gth c

apacit

y:

   D

et

er

mined

 b

y siz

e of 

st

or

age
 

                             

 lo

cat

ion

Ma
ter

ial:
   6061 

Al

u

minum

Fi

n

ish:
     

  P

o

we
r U

nit:
  Go
ld

 A

n

o

di

ze

             

 Ha
w

se

 P

ip

e:

  G

old 
or

 C

lear 

A

n

o

di

ze

CM-8 

DI

MENSI

O

NS

Vertical 

Extension 

kit

NEW postion for

Out-limit switch /

Guide Roller

Assembly

Out-limit switch /

Guide Roller

Assembly normal

position

Summary of Contents for Cablemaster

Page 1: ...Conway SC 29526 Phone 843 399 6146 Fax 843 399 5005 www glendinningprods com G G G G L L L LE E E EN N N ND D D DI I I IN N N NN N N NI I I IN N N NG G G G C CABLEMASTE ABLEMASTER R Shore Power Cable...

Page 2: ...nsists of two major components the hawse pipe and power unit The chromed hawse pipe is designed to accommodate varying sizes of shore power cables with the attached 30 or 50amp shore power plug cover...

Page 3: ...ble The CM 4 usually comes attached to it s own storage container to make installation as easy as possible You may also order the CM 4 with TV telephone cable installed instead of 30 amp shore power c...

Page 4: ...so be careful to remember that the selection of the hawse pipe location is in a large measure determined by the prop er location of the power unit and cable storage area Be sure that the hawse pipe s...

Page 5: ...limit switch by extending the wire to the relay box Fig 4 OTHER INSTALLATION OPTIONS Any number of mounting arrangements can be accomplished using the PVC pipe to remote mount the power unit or guide...

Page 6: ...gh a PVC pipe you are now ready to wire the Cablemaster to the boat s DC electrical system If the shore power cable is being direct ed vertically through PVC pipe see drawing below it is necessary to...

Page 7: ...limit swithch which is connected to the 1 and 2 terminals on the barrier strip is activated when the plug cover touch es the switch The out limit switch which is connected to the 3 and 4 terminals of...

Page 8: ...or in the appropriate hole with the optional bezel see accessories In each case the power switch must be protected by the neoprene cover to prevent the intrusion of moisture The relay box is mounted o...

Page 9: ...con nection to the electrical system E CABLE ADJUSTMENT Shore power cable diameters vary from one cable manufacturer to another the Cablemaster s main pulley is split in half and proper friction adjus...

Page 10: ...xes receptacles breakers and other enclosures in which electrical connections are made should be waterproof or be installed in a protected area Electricity enters the boat through the power cable The...

Page 11: ...l either no power or unit has power and does not respond Tripped breaker Power wire incorrectly connect ed to relay assembly Defective motor Defective relay box Reset breaker Replace relay assembly Wi...

Page 12: ...mp 220 v Adjustable 7 8 1 1 4 dia Length capacity Determined by size of storage location CM 7 DIMENSIONS 5 5 127 mm Hawse Pipe Flange Dim 5 x 6 1 2 3 1 2 89 mm 4 3 4 121 mm 9 3 4 248 mm 15 3 4 400 mm...

Page 13: ...DIMENSIONS Specifications Voltage Amperage Dimensions Weight Capacity Length of cable 12v DC or 24v DC 4 5 amps under load 5 1 2 L x 6 W x 10 H power unit only 9 lbs 30amp 110 volt cable 3 4 diameter...

Page 14: ...8 3 8 213 mm 4 102 mm SPECIFICATIONS Voltage 12v DC 24v DC available Current 7 11 Amps under load Weight 40 lbs Power unit 12 lbs Hawse pipe Cable size up to 2 gauge 5 conductor 100amp Adjustable 1 32...

Page 15: ...ASSEMBLY 50421 HINGE 50420 CAP RELAY ASSEMBLY 04034 12 24 VOLTS 70005 U BOLT 2X 65001 Spacer 50415 CHASSIS COVER 50414 CHASSIS 04812 IN LIMIT SWITCH ASSY incl switch 2 ft wire assy protective boot 048...

Page 16: ...mt Yellow or Purple ORANGE BLACK OFF OUT IN POWER SWITCH RED WHITE BLACK IN LIMIT SWITCH OUT LIMIT SWITCH M 12 or 24v MOTOR BATERY POSITIVE BATTERY NEGATIVE WHITE RED BLACK CABLEMASTER WIRING DIAGRAM...

Page 17: ...DINNING MARINE PRODUCTS INC for instructions concerning removal and shipping of the defective component Upon compliance of the foregoing procedure all warranted defects will be repaired or at GLENDINN...

Page 18: ...ge of transmitter Relay Unit required for addition of Remote on CM 4 models 85448 85424 85420 85421 POWER CABLE STORAGE CONTAINERS rotationally molded styrene containers used to store shore power cord...

Page 19: ...DOUS MISUSE CAN RESULT IN FIRE OR DEATH BY ELEC TRICAL SHOCK PLEASE READ CAREFULLY AND FOLLOW INSTRUCTIONS HAZARDS STATEMENT N OR SEND VIA FAX TO 843 399 5005 A cord reel marked for indoor use is to b...

Page 20: ...SML CMMAN PRINT DATE 06 08 740 CENTURY CIRCLE CONWAY SC 29526 8274 USA PRODUCT WARRANTY INFORMATION PLACE STAMP HERE Diameter 3 5 8 cut on outside of line Diameter 17 64 4 Plcs Hawse Pipe Template...

Reviews: