SMB9675-1A-1-7091:
When using SMB9675-1A-1-7091, type “sc6” at the “Terminal” window, and press the
“Enter” key. Repeat the same steps for “sc7”, “sc8”, and “sc9”.
Setup is completed.
4.6 Rigid Tap Test (Optional)
If desired you can test the rigid tap mode of your VMC by performing the following
procedure. This procedure is drawn from the FADAL maintenance manual.
Install test screw (SVT-0077). The screw can be fabricated from 1.000”
round stock, by threading a 14 TPI Acme thread.
Program is for Format 1. Use test program #6000 or the following program:
%
N1O6000(RIGID TAP CYCLE
N2G80
N3S750
N4G91
N5X0.1Y0.1G1F10.
N6M5
N7G4P2000
N8G84.1Z-1.R+0F500.Q0.0714
N9M45
N10X-0.1Y-0.1G1F10.
N11M45
N12M45
N13M45
N14M45
N15G80
N16G4P2000
N17M99P5
N18(!
N19( NOTE: O5827 CNC88 TEST WAS MOVED TO TA,5!!!
%
3801