18
Do not store near a heat source or in direct sunlight. Keep the terminals dry, clean and
coat lightly with petroleum jelly to prevent corrosion.
Batteries must be fully charged every 3 months if not in use.
Battery installation and removal
Battery installation should be carried out by qualified Technician.
1. Remove footrests and set Seat Tilt to approx. 20 degree. If no batteries installed,
discount seat actuator cable from Power module or ISM and using suitable connection
cable, connect seat actuator to battery (12v is ok) and operate actuator until seat tilts to
20 degrees..
2. Remove 4 securing blots holding down Seat Base module.
3. Apply Park Brake and using Back Cane push handles, tilt seat base forward. Remove
battery cover and attached security hook
as illustrated below.
4. Unscrew and remove circuit breaker.
5. To avoid accidental shorting of batteries when installing, ensure terminal protection
caps are installed. If not, then use insulation tape and cover all terminals.
6. Orientate front battery and lift into back of Battery Box and slide forward. Orientate
rear battery and lift into battery box. Secure battery using tie down bolts and clamps
7. Connect all wires in accordance to wiring diagram page 20.
8. Once completed, detach security hook and swing hook to back of chair and locate in
holder. Insert plastic Battery Cover on top of batteries (ensure correct orientation) and
lower Seat Base back down to chassis. Insert 4 bolts into base plate and chassis and
tighten nuts.
Please adhere to Battery installation Warnings on page 20
Note: Vertical Lift seat models (post 2013) will hinge from rear of wheelchair.