background image

Global Connect 

User Guide 

 

 

Global Connect User Guide 

160 East California Street, PO Box 1659 

Effective: January 10, 2019  

Jacksonville, Oregon 97530 

PN: 103118-01 ver. 1 

Phone: 541-899-4800 

Page 1  

Fax: 541-899-4808 

www.globalcache.com

 

Information subject to change without notice.

 

1.0 INTRODUCTION 

Global Caché's modular Global Connect is the newest high-performance family of connectivity products from the company 
that has revolutionized the way you connect, command, and control. Built with performance, flexibility, and empowering in 
mind, Global Connect delivers a simple cost-effective way to extend the reach of any control system, from legacy hardware-
based systems to leading-edge cloud-based control software; from current projects to future installations. 

 

Known for award-winning products connecting infrared (IR), serial (RS232 and 485), relay, and sensor input, to a WiFi or IP 
network, Global Caché introduces Global Connect, adding the ability to build the scalable I/O you need, with customizable 
configuration, and added modules including local computing capability (Raspberry Pi slot), and HDMI switching. Global 
Connect features individual IP addresses for each module with individual web pages for easy configuration and advanced 
addressability. 

This document intends to provide additional information, insight, and instruction on installing, configuring, and using Global 
Connect.   

For initial setup instructions, or TCP and HTTP APIs please refer to the 

Global Connect Quick Start

, or Global Connect 

APIs

 

respectively on our downloads page:

  http://www.globalcache.com/downloads 

 

 

Summary of Contents for Global Connect

Page 1: ...d based control software from current projects to future installations Known for award winning products connecting infrared IR serial RS232 and 485 relay and sensor input to a WiFi or IP network Globa...

Page 2: ...Module 4 5 2 GCSW GCSW P Dual Ethernet Network Switch Module 5 5 3 Network Settings 5 5 3 1 DHCP and DHCP reservations 6 5 3 2 Static IP addresses Advanced 7 6 0 GCHMX3 HDMI 3x1 switching Module 9 6...

Page 3: ...ity with previous Global Cach product drivers Drivers for previous products should generally be expected to work on Global Connect devices assuming the Global Connect functionality existed on the prod...

Page 4: ...odule also provides the power input for the entire unit Network modules can be powered with any power supply between 5v and 24V DC All Global Connect units ship with an appropriately rated power suppl...

Page 5: ...ge 5V 24V Power over Ethernet PoE capability GCSW P only 802 3af Powered Device PD Chassis Slots Occupied 2 5 3 NETWORK SETTINGS Network settings for Global Connect units are set individually on each...

Page 6: ...Many control apps and systems expect the IP address of Global Connect modules to remain the same If the IP address of a module changes which can happen when using DHCP the control software may not be...

Page 7: ...t somewhere under DHCP settings When setting a DHCP reservation the MAC address of the module is associated with the IP address it should be assigned This allows the DHCP server to assign the reserved...

Page 8: ...gned a non communicable IP address one simple way to recover the module is to perform a factory default as explained in section 11 0 Configuration Example To set a static IP address assignment navigat...

Page 9: ...8Gbps 4K Resolutions UHD 4K 60Hz 4 4 4 8 bit UHD 4K 60Hz 4 2 2 8 bit 10 bit 12 bit UHD 4K 60Hz 4 2 0 8 bit 10 bit 12 bit Chassis Slots Occupied 2 6 1 CONSUMER ELECTRONIC CONTROL CEC Consumer Electroni...

Page 10: ...p options can be configured in the chosen control software 7 0 GCIR3 INFRARED IR CONTROL MODULE Infrared IR is a common control type and is commonly used for AV control but also used in applications f...

Page 11: ...k shiny plastic and are typically placed as close to the front of the device s enclosure as possible IR Blasters IR Blasters are long range IR transmitters Long range IR transmitters are designed to c...

Page 12: ...r use learning IR codes https www globalcache com downloads A tutorial for learning IR codes with iLearn is available on our website https www globalcache com support ilearntutorial Information about...

Page 13: ...els If those codes fail or no similar devices are available then the IR codes will either need to be learned using iLearn section 7 2 or obtained from a 3rd party source in which case they are often i...

Page 14: ...cts RS232 devices to a network and includes an easy to use highly configurable web interface GCSL232 Module Feature Description Ports 1 x Male DB9 Baud Rate 300 115200 baud Flow Control Hardware None...

Page 15: ...m Information subject to change without notice 8 2 DB9 PINOUT The DB9 connector is a common connector for RS232 interfaces Typically RS232 devices will either have a male or female DB9 connector The d...

Page 16: ...2 to a serial device the correct cable must be used The following table lists the correct cable type that should be used when connecting the GCSL232 to serial devices with the DB9 connector Gender of...

Page 17: ...mpatible Wire Gauges Connector 14 30 AWG Relay Type Normally Open NO Chassis Slots Occupied 2 Configuration example To access the relay configuration settings navigate to the Relay Settings page on th...

Page 18: ...he relay is turned on and off when the relay is turned off To confirm that the relay is physically closing or opening a continuity test can be used Disconnect all wires from the relay terminal blocks...

Page 19: ...pied 3 For more information on the Raspberry Pi 3 specifications please visit the Raspberry Pi Foundation s web site https www raspberrypi org Configuration of the Raspberry Pi module is based on the...

Page 20: ...rry Pi can become the controller for the automation system and run automations macros and triggers depending on the needs of the system 11 0 FACTORY DEFAULT To factory default a Global Connect unit lo...

Reviews: