background image

Installation

Choosing The Right Location

Your installation location should meet the following requirements:

-Make sure that you install your unit on an even surface to minimize 

 noise and vibration. 

-The unit must be installed near a grounded plug, and the Collection 

 Tray Drain (found on the back of the unit) must be accessible. 

-The unit should be located at least 30cm (12”) from the nearest wall 

 to ensure proper air conditioning. 

-DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the 

 unit, as this could cause damage to the unit. 

NOTE:

All the illustrations in the manual are for explanation 

purpose only.  Your machine may be slightly different. 

The actual shape shall prevail.

The unit can be controlled by the unit control panel alone or 

with the remote controller. This manual does not include 

Remote Controller Operations, see the <<Remote Controller

Instruction>> packed with the unit for details. 

6

Recommend Installation

50cm

19.7inch

Summary of Contents for 292781

Page 1: ...Model 292781 ...

Page 2: ...Contents 1 Preparation Safety Precautions Cautions Installation Operation Mai ntenance Faults Diagnosis Design and Compliance Notes Sociable Remark 2 4 5 6 10 13 14 15 16 ...

Page 3: ...s horizontal louver control lever adjust manually NOTE PHA can not be adjusted NOTE PHA can not be adjusted vertical louver control lever adjust manually panel Caster bottom tray drain outlet air filter behind the grille upper air intake air outlet lower air intake drain outlet 2 ...

Page 4: ...Preparation NOTE The unit you purchased may be look like one of the followings 3 ...

Page 5: ...r laundry room Too much exposure to water can cause electrical components to short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause fire The unit has wheels to facilitate moving Make sure not to use the wheels on thick carpet or to roll over objects as these could cause tipping DO NOT operate a unit that it has been dropped or damaged The appl...

Page 6: ...der to avoid a hazard Prior to cleaning or other maintenance the appliance must be disconnected from the supply mains Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord awa...

Page 7: ... from the nearest wall to ensure proper air conditioning DO NOT cover the Intakes Outlets or Remote Signal Receptor of the unit as this could cause damage to the unit NOTE All the illustrations in the manual are for explanation purpose only Your machine may be slightly different The actual shape shall prevail The unit can be controlled by the unit control panel alone or with the remote controller ...

Page 8: ...rol models only Press the exhaust hose into the window slider adaptor and unit adaptor clamp automatically by elastic buckles of the adaptors Push the Exhaust hose into the airoutlet opening of the unit along the arrow direction Unit adaptor Window slider adaptor Exhaust hose Exhaust hose assembly Step One Preparing the Exhaust Hose assembly Step Two Install the Exhaust hose assembly to the unit S...

Page 9: ... between the glass and the window frame to prevent air and insects from getting into the room If desired install the security bracket with 2 screws as shown Insert the window slider adaptor into the hole of the window slider Insert the window slider assembly into the window opening Insert the window slider assembly into the window opening Type 1 Hung Window Installation Foam seal B Adhesive type s...

Page 10: ...indow slider adaptor into the hole of the window slider Foam seal C Non adhesive type 2 Screws Security Bracket Note To ensure proper function DO NOT overextend or bend the hose Make sure that there is no obstacle around the air outlet of the exhaust hose in the range of 500mm in order to the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your a...

Page 11: ... Down buttons at the same time for 3 seconds Power button Power switch on off Power indicator light Timer mode indicator light set only by remote controller Up and Down buttons LED display Shows the set temperature while on cool mode While on DRY and FAN modes it shows the room temperature Shows Error codes E1 Room temperature sensor error E2 Evaporator temperature sensor error E4 Display panel co...

Page 12: ...ect Do not put the duct to window AIR FLOW DIRECTION ADJUSTMENT Adjust the air flow direction manually The louver can be set to the desired position manually Do not place any heavy objects or other loads on the louver doing so will cause damage to the unit Ensure the louver is fully opened under heating operation Keep the louver fully opened during operation Other features FOLLOW ME TEMP SENSING f...

Page 13: ...flow smoothly When the continuous drain hose is not used ensure that the drain plug and knob are installed firmly to prevent leakage Remove the drain plug Continuous drain hose When the water level of the bottom tray reaches a predetermined level the unit beeps 8 times the digital display area shows P1 At this time the air conditioning dehumidification process will immediately stop However the fan...

Page 14: ... airflow due to animal hair Remove the air filter Air filter take out WARNING Maintenance 13 CAUTION DO NOT operate the unit without filter because dirt and lint will clog it and reduce performance Clean the Unit Store the unit when not in use Clean the unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to th...

Page 15: ...onnected or is blocked The Water Collection Tray is full Turn off the unit drain the water from the Water Collection Tray and restart the unit There are heat sources inside the room Turn off the unit and clean the filter according to instructions Call a service technician to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Double chec...

Page 16: ...ded exhaust duct without window slider adaptor as shown in the Installation section of this manual At the same time the unit must be operate on the COOL MODE and HIGH FAN SPEED by remote controller Unit Temperature Range Cool 17 35 C 62 95 F Dry 13 35 C 55 95 F Mode Temperature Range 15 Exhaust hose installation The exhaust hose and adaptor must be installed or removed in accordance with the usage...

Page 17: ...e municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal...

Page 18: ...CP027IU PH US XBDOE 16120600000495 ...

Page 19: ...说明书纸张规格 290 210 材质 铜版纸105g 印刷内容黑白 此页内容不需要印刷 封面后不能加空白页 要印目录页内容 ...