Step 1: Determine the location for installation (Make sure all ADA requirements are
met).
***NOTE: The installation of Global Lift Corp’s anchor system’s are a guideline of
minimum requirements. In some states or municipalities they may require additional
steps due to their local codes or ordinances.***
Step 2: Make sure that all the parts are present (Refer to the parts list)
1 - Anchor Sleeve w/ Base
1 - Binding Screw
1 - Plastic Cap
Step 3: At the determined location for installation, chalk out a 3’ X 3’ area prior to
cutting out the concrete. (Refer to overview, the front end of the Anchor Sleeve
must be 12” to 17” from the water’s edge and 6” deep). New Construction, the
concrete must be 6” deep with a ½” reinforcing rod, minimum of an 18” grid.
NOTE: Make sure that all local codes and ordinances are met.
Step 4: Once the 3’ X 3’ area is cut out, make sure you drill in the inner wall of all 4
sides of the area (refer to the section detail) for the purpose of cold pinning the new
concrete to the old concrete. Use 1/2” rebar, 6” to 8” in length.
FEB 2012
Superior New Construction/Saw Cut
Anchor