www.globallightllc.com
info@globallightllc.com
Fax: +971 4 341 10 90
Tel: +971 4 340 44 58
•
Step 4:
Connect the luminaire input cable to the main power supply (12V) cable (Do not cut the main
power supply cable, just remov e insulation, twist the luminaire input cable around the main cable). Ensure
the junction box is installed within one meter from the luminaire as illustrated.
•
Step 5:
Solder the connections, wrap the connection with 3M waterproof tape first and then electrical
tape and keep all the connections inside the junction box and put silicon on the top surface of the
junction box and close the junction box with screws as illustrated.
•
Step 6:
Adjust the luminaire angle by thumb nut as illustrated.
Make sure the main power is switched off during installations.
DO NOT
CUT MAIN
CABLE
No. of fixtures
Wattage
Total Wattage
Wire size
25 - 15
3W - 6W
90W
2.5mm²
35 - 20
3W - 6W
120W
4mm²
55 - 30
3W - 6W
180W
6mm²
75 - 40
3W - 6W
240W
10mm²