Step 4: 

Connect the luminaire input cable to the main power supply (12V) cable (Do not cut the main 

power supply cable, just remov e insulation, twist the luminaire input cable around the main cable). Ensure 

the junction box is installed within one meter from the luminaire as illustrated.  

 

 

 

 

 

 

 

 

Step 5: 

Solder the connections, wrap the connection with 3M waterproof tape first and then electrical 

tape and keep all the connections inside the junction box and put silicon on the top surface of the 

junction box  and close the junction box with screws as illustrated. 

 

 

 

 

 

 

 

 

Step 6: 

Adjust the luminaire angle by thumb nut as illustrated. 

 

Make sure the main power is switched off during installations.

 

 

DO NOT 

CUT MAIN 

CABLE 

No. of fixtures 

Wattage 

Total Wattage 

Wire size 

25 - 15 

3W - 6W 

90W 

2.5mm²   

35 - 20 

3W - 6W 

120W 

4mm² 

55 - 30 

3W - 6W 

180W 

6mm² 

75 - 40 

3W - 6W 

240W 

10mm² 