Step 7:
Connect the luminaire input cable to the main power supply (12V) cable (Do not cut the main
power supply cable, just remov e insulation, twist the luminaire input cable around the main cable). Ensure
the junction box is installed within one meter from the luminaire as illustrated.
•
Step 8:
Solder the connections, wrap the connection with 3M waterproof tape & electrical tape and keep
all the connections inside the junction box . Put silicon on the top surface of the junction box and close
the junction box with screws as illustrated.
•
Step 9:
Adjust the luminaire angle by thumb nut as illustrated.
Make sure the main power is switched off during installations.
DO NOT
CUT MAIN
CABLE
No. of fixtures
Wattage
Total Wattage
Wire size
25 - 15
3W - 6W
90W
2.5mm²
35 - 20
3W - 6W
120W
4mm²
55 - 30
3W - 6W
180W
6mm²
75 - 40
3W - 6W
240W
10mm²