13
CAUTION.
Over stretching the rubber straps may result in
fracturing the straps.
6. Reconnect the tank 1 inlet hose (25) onto the combination
valve (8), by depressing and sliding back the sleeve of
the quick coupler valve while reconnecting the hose.
7. Open the tank 1 isolation
valve (18).
Note.
When the isolation
valve is opened and there is is
compressed air in the lower tank
you will hear the air equalise into
the top tank.
The portable air tank has been
properly installed and connected
to the air compressor unit. Your
air compressor is now ready
for use.
WARNINGS.
1. Never attempt to remove any electrical component whilst
the compressor is connected to the power supply. Switch
off the power and remove the electrical plug.
2. Do not adjust the safety valve.
3. Do not use an electrical extension cable.
4. Ensure that the lubricating oil is clean and that the oil
level is maintained at the mid point of the red circle in the
oil sight glass (16).
5. Take care when discharging air from the tank, i.e. from
the safety valves (7), the drain cocks (9) or the air outlets
(4 and 27). Compressed air can be extremely dangerous.
Take care the discharge air does not cause dust, stones
or any other foreign particles to be blown through the air
and that the air is discharged in a safe manner.