Appendix A: Optional Equipment Mounting Instructions   

 

Barometric Pressure Sensor Mounting Instructions 

a.

 

The barometric pressure sensor should be mounted in a manner that 
protects it from the elements, but exposes it to the air.  Global Water 

recommends mounting it in some type of weather resistant enclosure 
that is vented.  If this is not practical the sensor can be mounted, with 
the sensing nozzle face down, on the station’s stand using a hose 
clamp or other type of strap.   

 

Solar Radiation Sensor Mounting Instructions

 

a.

 

The Solar Radiation Sensor comes with mounting hardware similar to 
the Wind Direction and Wind Speed Sensors.   

b.

 

The T fitting and stub should be mounted on the upper portion of the 
mast and secured at a height and in a direction where the sensor will 
not be shaded by any other sensor of object.  Tighten the T fitting’s set 
screws with the enclosed allen wrench to secure the stub in place.  

c.

 

The Solar Radiation Sensor has a 1” elbow that mounts on the stub.  
Place the elbow on the stub and secure with the set screw. 

 
 

Tipping Bucket Mounting Instructions 

a.

 

See Tipping Bucket manual for installation instructions.  

 

Solar Panel Mounting Instructions

 

d.

 

The Solar Panel comes with mounting hardware similar to the Wind 
Direction and Wind Speed Sensors.   

e.

 

The T fitting and stub may be mounted any where on the mast as long 

as the solar panel faces the sun’s general path across the sky, refer to 
the solar panel manual for further instructions, available online at, 

www.globalw.com

, in the downloads section.  Tighten the T fitting’s set 

screws with the enclosed allen wrench to secure the stub in place.  

f.

 

The Solar Radiation Sensor has a 1” fitting that mounts on the stub.  
Place the fitting on the stub and secure with the set screw. 

 

 

 
 
 
 

Summary of Contents for WE900

Page 1: ...Global Water 800 876 1172 globalw com 1 Global Water Instrumentation Inc 11257 Coloma Road Gold River CA 95670 T 800 876 1172 Int l 916 638 3429 F 916 638 3270 4 20mA Weather Station WE900 5 28 02...

Page 2: ...E900 to be a valuable asset for your application Should you require assistance our technical staff will be happy to help Table of Contents I Checklist Page 3 II Inspection 3 III Description 3 IV Insta...

Page 3: ...fied by Global Water s Quality Assurance Team before shipping If any damage has occurred during shipping please notify Global Water Instrumentation Inc and file a claim with the carrier involved Use t...

Page 4: ...ert to complete the mast f Mount the cross bar to the top of the mast using the attached T fitting Tighten the set screw with the enclosed allen wrench Ensure that the cross bar is level NOTE For best...

Page 5: ...er to the Weather Sensor manual to determine how often each sensor should have its calibration checked VI Specifications a Refer to the Weather Sensor manual for individual sensor specifications b 4 2...

Page 6: ...equipment needs to be returned to the factory for any reason please call to obtain a RMA Return Material Authorization DO NOT return items without a RMA on the outside of the package Include a writte...

Page 7: ...ption I replacing or II repairing any products determined to be defective In no case shall Global Water s liability exceed the products original purchase price This warranty does not apply to any equi...

Page 8: ...where the sensor will not be shaded by any other sensor of object Tighten the T fitting s set screws with the enclosed allen wrench to secure the stub in place c The Solar Radiation Sensor has a 1 elb...

Reviews: