background image

- 4 - 

 

      TROUBLE SHOOTING

             

                TROUBLE SHOOTING                       

 

 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FAULT 

CAUSE 

SOLUTION 

 
Unit does 
not 
operate 

 
No power to 
machine. 
 

Plug in unit; check 
power at outlet and 
at base of unit. 
Confirm power is 
on. 

Fan is not 
turning 

Obstructed air   
Outlet. 

Remove 
obstruction.   
 

Unit 
operating, 
but room 
not dry   

1. Insufficient 
Dehumidifying 
time. 
2. Poor air 
circulation 
in room. 
3. Excessive 
moisture in room. 

1. Allow more time 
for drying. 
2. Increase air 
circulation with fans. 
3. Reduce external 
air infiltration into 
the room. 

 
Unit 
collects 
minimal 
water   

1. Room air is dry.   
2. Obstructed filter   
and coils 
3.Room 
temperature   
is too low.   

1. Check humidity 
with hygrometer.   
2. Check filter and 
coils. Clean as 
necessary.   
3. Increase room 
temperature. 

 
WARNING: 
DO NOT attempt to rectify issues with unqualified 
personnel. 
If the problem you are experiencing is not listed 
here, contact Global Industrial Customer Service. 

 

CODE 

ER1 

ER2 

ER4 

 
Error 
message 

 
Coil sensor 
error 

 
Humidity 
sensor error 

 
Water pump 
fault or 
blockage 

 
Display 
Reading 

 
Flashes every 
one second 

 
Flashes every 
one second 

 
Flashes 
every one 
second 

 
 
 
 
Reason 

 
1. The coil 
sensor terminals 
are not securely 
plugged in. 
2. The coil 
sensor is 
damaged.     
3. If unsolved, 
there may be a 
display panel 
PCB issue. 

 
1. The humidity 
sensor 
terminals are 
not securely 
plugged in. 
2. The humidity 
sensor fault.     
3. If is unsolved, 
It may be 
display panel 
PCB issue 
question. 

 
 
Water is not 
draining from 
the pump 
reservoir or 
there is a 
lack of power 
to the water 
pump. 
 

 
 
 
 
Remedy 

 
1. Verify coil 
sensor terminal 
is securely 
plugged in. 
2. Replace the 
coil sensor. 
3. Replace 
display panel 
PCB 

 
1. Verify 
humidity sensor 
terminal 
securely 
plugged in. 
2. Replace the 
humidity sensor. 
3.Replace 
display panel 
PCB 

 
1. Make sure 
maximum lift 
is not 
exceeded.   
End of hose 
should not 
be higher 
than 10ft. 
above unit. 
2. Check 
pump for 
debris or 
blockage. 

 

NOTE:   

The table above shows error messages that the system may 

detect. If the display shows an 

“ER” message, 

Unplug the unit and reinsert. This may reset the electronics, and 

if issue is resolved, no further action is required. 

If error message reappears, complete the following 

troubleshooting steps under 

“Explanation.” If this still does not 

rectify the issue, contact Global Industrial customer service at 

1-800-645-2986. 
 