6. CONNECT WATER INLET LINES

•  Install a shut-off valve (not included) on the water supply.

•  All water connections and drains must comply with local codes.
Though the rear access windows, connect water inlet lines as illustrated below:

Connect (P5) to Spout

Connect Inlet Adapter (P2) to

Union T-Connector (P3)

Connect (P5) to Bubbler

P6

(21-3/4”)

Outdoor Bi-Level Drinking Fountain

w/ Bottle Filler & Pet Station

Connect (P5) to Push Button

Connect (P6) to Straight

Flow Check Valve (P4)

(See Fig. 1 on next page)

INSTALL SHUT-OFF VALVE

(NOT INCLUDED)

P6

(2”)

P5

(6-1/4”)

P5

(6-1/4”)

P5

(39-1/4”)

P5

(25-1/2”)

P5

(6-1/4”)

P5

(25-1/2”)

Summary of Contents for 761221

Page 1: ... repair or replace any part of this fountain unless it is specifically recommended in this manual All other services should be referred to a qualified technician For use with clean clear potable drinking water only Shut off water supply during installation to reduce the risk of water damage Freezing Caution Before freezing temperatures occur refer to the Draining and Winterization section of this ...

Page 2: ... BOTTLE FILLER PEDESTAL SPOUT DRAIN PAN DRINKING FOUNTAIN BUBBLER DRAIN PUSH BUTTON PET STATION PEDESTAL ARM BASE COLOR OPTIONS WWW GLOBALINDUSTRIAL COM SS316 SS316 GREEN SS316 BLACK SS316 BLUE 2 1 4 3 1 2 3 4 BOTTLE FILLER DRINKING FOUNTAIN PET STATION OUTDOOR PEDESTAL 5 HARDWARE BAG ...

Page 3: ... Head Screwdriver Ref Qty Descrip on Ref Qty Descrip on P1 3 Bubbler P2 4 Inlet Adapter P3 3 Union T Connector P11 6 Drain Tubing P4 1 Straight Flow Check Valve P12 1 Offset Drain Tubing P5 8 1 4 O D Water Inlet H1 1 Torx Key Wrench P6 4 3 8 O D Water Inlet H2 1 Torx Drill Bit P7 12 Pipe Insula on H3 4 Anchor Kit P8 1 Straight Drain Connector H4 8 M6 x 10 Pan Head Screw 1 39 1 4 2 25 1 2 3 6 1 4 1 ...

Page 4: ... Station 9 225mm 16 376mm 40 1023mm 29 753mm 16 412mm 6 152mm 6 158mm 7 1 2 191mm ORIFICE HEIGHT 29 755mm ORIFICE HEIGHT 28 1 2 723mm 18 1 2 475mm 8 1 2 215mm 22 565mm 60 1 4 1531mm 36 1 2 922mm 10 1 4 260mm 10 260mm 10 260mm 14 355mm 27 691mm 47 1 2 1211mm 1 8 46mm 18 1 2 475mm 27 689mm 33 1 4 847mm 34 1 2 880mm ORIFICE HEIGHT 1 2 12mm HOLES 4 FINISHED FLOOR 1 1 2 WASTE A C 11 1 2 300mm 7 177mm 5...

Page 5: ... is rated for inlet water pressure of 20 105 PSI A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI Any damage caused by reason of connecting this product to supply line pressure higher than 105 PSI will void warranty 1 REMOVE ACCESS PANELS To gain access to the drain and water line connections remove all access panels detailed below using the provided torx key ...

Page 6: ...ing and secure to ground using provided anchor kit H3 mounting hardware x4 2 INSTALL BUBBLERS 2a Unscrew and remove nut and washers from Bubblers P1 2b Locate the hole on the drinking fountain pan surfaces Align and sanwich with the two washers and tighten the nut to secure the bubbler 2c Bubblers are now properly installed H3 Anchor kit consists of 4 M10 Nuts 4 M10 Lock Washers 4 M10 Standard Was...

Page 7: ...4 x8 M6 x 10 pan head screws H5 H6 H7 qty 8 H4 qty 4 qty 4 qty 4 5 ATTACH DRINKING FOUNTAIN TO PEDESTAL 4 ATTACH BOTTLE FILLER TO PEDESTAL Assemble to the drinking fountain to the pedestal using H5 x4 H6 x4 and H7 x4 hardware Tighten all nuts securely using an adjustable wrench Outdoor Bi Level Drinking Fountain w Bottle Filler Pet Station ...

Page 8: ...ndows connect water inlet lines as illustrated below Connect P5 to Spout Connect Inlet Adapter P2 to Union T Connector P3 Connect P5 to Bubbler P6 21 3 4 Outdoor Bi Level Drinking Fountain w Bottle Filler Pet Station Connect P5 to Push Button Connect P6 to Straight Flow Check Valve P4 See Fig 1 on next page INSTALL SHUT OFF VALVE NOT INCLUDED P6 2 P5 6 1 4 P5 6 1 4 P5 39 1 4 P5 25 1 2 P5 6 1 4 P5 ...

Page 9: ...king fountain is being installed in areas where cold temperatures may occur wrap pipe insulation P7 around all water inlet lines Installation of a trap on the water drain line may be necessary check local codes Always remove trap before winterization draining CAUTION Before freezing temperatures occur see Draining and Winterization section of this manual page 13 for proper preparation P4 Straight ...

Page 10: ...tallation of a trap on the water drain line may be necessary check local codes Outdoor Bi Level Drinking Fountain w Bottle Filler Pet Station P11 16 3 4 Connect P9 to Drinking Fountain Drain and insert P11 Connect all 3 Drain Tubes to P10 Connect P8 to Bottle Filler Drain and insert P12 Connect P9 to Drinking Fountain Drain and insert P11 P11 3 3 4 P11 16 3 4 P11 19 P11 2 1 2 P11 14 1 4 Confirm wi...

Page 11: ...moved from the fountain WARNING Flush all water supply lines thoroughly before initial use SIDE VIEW FRONT VIEW Outdoor Bi Level Drinking Fountain w Bottle Filler Pet Station Confirm with local codes for trap and other drainage requirements P10 P11 Reinstall access panel on the base of the pet station pan BEFORE connecting P11 Drain Tube to P10 T Shape Drain Connector using 8 M6 x 10 flat head ant...

Page 12: ... due to air in the water lines this will be eliminated once air is purged from all water lines Press and hold the push button until a steady water stream is achieved H8 x4 8 ATTACH PET STATION TO PEDESTAL Using provided torx key wrench H1 or torx drill bit H2 attach the pet station to the pedestal using H8 x4 M6 flat head screws ...

Page 13: ...the adjustment screw Turn clockwise to raise the stream height and counterclockwise to lower the stream height For best adjustment the stream should be approximately 1 1 2 above the top of the bubbler see FIG 3 FIG 3 1 1 2 Before freezing temperatures occur turn off the water at the shut off valve disconnect the water supply line tubing and blow out lines Press down on push button to release any a...