USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- TROUBLESHOOTING
Revision: No. 1
26
4.2.2 Fitting resistance outside margins (BEAT-2):
Once the electrofusion process has begun and where data is captured exclusively by
barcodes, if the fitting resistance is higher than the tolerances established by the fitting’s
manufacturer, the display will show:
FAILURE OF FITTING
RESISTENCE TOO HIGH
If this message persists, send the unit the After-Sales Service to check the calibration of
the resistance measure.
Once the electrofusion process has begun and where data is captured exclusively by
barcodes, if the fitting resistance is lower than the tolerances established by the fitting’s
manufacturer, the display will show:
FAILURE OF FITTING
RESISTENCE TOO LOW
If this message persists and after checking the that fitting and barcode resistance are
correct, send the unit the After-Sales Service to check the calibration of the resistance
measure.
4.2.3 Interruption by operator:
If the operator presses the <STOP> key once the electrofusion process has begun, the
display will show:
<STOP> PUSHED
xxxxs
Where xxxxs corresponds to the remaining
cycle time at the moment of stopping.
4.2.4 Output current:
If the electrofusion current is excessive, the display will show:
CURRENT TOO HIGH
xxxxs
Where xxxxs corresponds to the remaining
cycle time at the moment of stopping.
This message appears in the following cases:
1. When the connected fitting has a very low resistance, outside the margins.
2. Crossed fitting resistence.
If the electrofusion current is too low, the display will show:
CURRENT TOO LOW xxxxs
Where xxxxs corresponds to the remaining
cycle time at the moment of stopping.