background image

 

Globalcom Engineering 

 

 

This document contains the proprietary information of Globalcom Engineering. Its receipt or possession does not convey any rights to 
reproduce or disclose its contents or to manufacture, use or sell anything it may describe. Reproduction, disclosure or use without specific 
written authorization of Globalcom Engineering is strictly forbidden.                                                                                           

Mod.N:Q060R04

 

14

 

6 BV1000CL CONNECTORS VIEW 

6.1 BV1000CL FRONT VIEW 

 

 

Four green leds follow the rule of EMVco, together with the buzzer, to monitor the transaction 
status. 
The following table specify the RGB LED sequence for a normal transaction, from card insert, 
through product selection and vend to card withdrawal. 
 

INDICATOR

 

STATE

 

DESCRIPTION

 

GREEN 

STATIC 

Ready For Use, Idle State 

RED 

STATIC 

Out Of Order 

YELLOW 

FLASHING 

Please Make Selection 

YELLOW 

STATIC 

Processing Transaction, Please Wait 

GREEN 

FLASHING 

Paid Remove Card 

RED 

FLASHING 

Error, Remove Card – No Payment Made 

 
Notes: 
The yellow led indicator is optional so if the reader uses only the red and the green leds, the 
sequence remains the same but with the yellow led states removed. 
 

DRAFT V01

Summary of Contents for BV1000CL

Page 1: ...y any rights to reproduce or disclose its contents or to manufacture use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden User Manual Revision R01 13 P N MAEU010 BV1000CL Contactless Unattended Reader D R A F T V 0 1 ...

Page 2: ...ENERAL SAFETY INFORMATION 7 2 2 BASIC RULES 7 2 3 IMPORTANT SAFETY INSTRUCTIONS 7 3 WARRANTY CONDITIONS 8 4 VIEW AND ORDER CODES 9 4 1 OVERVIEW 10 4 2 PACKING LIST 11 5 TECHNICAL SPECIFICATIONS 12 5 1 BV1000CL TECHNICAL SPECIFICATIONS 12 5 2 BV1000CL SPECIFICATIONS 13 6 BV1000CL CONNECTORS VIEW 14 6 1 BV1000CL FRONT VIEW 14 6 2 BV1000CL BACK VIEW 15 7 CABLE 18 7 1 CAC0096 POWER CABLE 18 7 2 CAC013...

Page 3: ...o 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz Part 1 Technical characteristics and test methods ETSI EN 300 330 2 Electromagnetic compatibility and Radio spectrum Matters ERM Short Range Devices SRD Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz Part 2 Harmonized EN covering the essential require...

Page 4: ...llation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment causes harmful interference to radio or television reception which can be determined by t...

Page 5: ...sure the correct disposal and recycle of this product contact your supplier The abandonment or inappropriate disposal of waste can cause harm to environment and harm to the human health By ensuring the correct disposal of this product you will help prevent negative consequences for the environment and human health also you will contribute to the preservation of the natural resources The device con...

Page 6: ...nmental Testing Part 2 14 Tests Test N Change of temperature CEI EN 60068 2 30 Environmental Testing Part 2 30 Tests Test Db Damp heat cyclic 12h 12h cycle CEI EN 60068 2 78 Environmental Testing Part 2 78 Tests Test Cab Damp heat steady state CEI EN 60068 2 6 Environmental Testing Part 2 6 Tests Test Fc Vibration sinusoidal Salt Mist test CEI EN 60068 2 11 Environmental Testing Part 2 11 Tests Te...

Page 7: ...nter into area for non operators Not allow liquid to spill into the internal cabinet side Not allow anything to rest on the power cord or telecomm cords and ensure a properly routing of all the cable to prevent damage or accidental contact Not continue to operate with the equipment if you are in doubt about its normal working or if the equipment has been damaged 2 2 BASIC RULES 1 The responsibilit...

Page 8: ...ge in the electric system caused by negligence in the use of the device not observation of the instructions of use or by reasons not attributable to manufacturing defects 4 The device has been modified to be used in a country different from the countries for which has been designed or where applicable homologated or has been damaged by those modifications 5 The warranty doesn t cover wearing parts...

Page 9: ... or disclose its contents or to manufacture use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 9 4 VIEW AND ORDER CODES PRODUCT CODE ORDER CODE DESCRIPTION 1ASA184H02 BV1000CL Compact Unattended Contactless Reader Ethernet Interface D R A F T V 0 1 ...

Page 10: ...balcom Engineering is strictly forbidden Mod N Q060R04 10 4 1 OVERVIEW BV1000CL is a low power unattended Contactless Reader for transaction in parking buses vending machines or ticketing kiosks BV1000CL can be used alone or with BV1000R contact reader BV1000CL is compliant with EMVco Contactless Specification BV1000CL is available with the following interfaces Serial Port USB OTG Ethernet GPRS do...

Page 11: ... without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 11 4 2 PACKING LIST Following are reported the packing lists for each orderable code 1ASA184H02 QTY CODE DESCRIPTION 1 1ASA184H02 BV1000CL Compact Unattended Contactless Reader Ethernet Interface with Globalcom Italian Keys 1 CAC0096 Cable BV1000R Power L 50cm Cables not included CAC0113 Cable BV10...

Page 12: ...us BUZZER Magnetic buzzer CONTACTLESS DRIVER CLRC663 SAM READER 2 SAM module connectors COMMUNICATION 4 RS 232 serial ports 1 USB 2 0 OTG 1 Ethernet 10 100MB POWER SUPPLY DC from 8V to 30V POWER CONSUMPTION 4W Max BATTERY BACK UP Primary Lithium SIZE 84 4 x 84 4 x 21 mm WxHxD CUT AREA 40 x 40 mm WxH WEIGHT 100 grams OPERATING TEMPERATURE 25 C 70 C STORAGE TEMPERATURE 30 C 80 C ENVIRONMENT Humidity...

Page 13: ... number generator dedicated hardware for protection against SPA DPA attacks and sensors to warranty the environment protection The second processor is a high performance ARM Cortex M4 32 bit RISC core operating at a frequency up to 168 MHz with memory protection unit MPU which enhances application security Contactless Chip Driver it s CLRC663 chip from NXP The CLRC663 is a highly integrated transc...

Page 14: ... rule of EMVco together with the buzzer to monitor the transaction status The following table specify the RGB LED sequence for a normal transaction from card insert through product selection and vend to card withdrawal INDICATOR STATE DESCRIPTION GREEN STATIC Ready For Use Idle State RED STATIC Out Of Order YELLOW FLASHING Please Make Selection YELLOW STATIC Processing Transaction Please Wait GREE...

Page 15: ...R04 15 6 2 BV1000CL BACK VIEW FIGURE 1 Connector View of the BV1000CL PSU Power supply Connector VD C ERNI P N 284696 or 101403240001 3 poles PIN1 VIN PIN2 GND PIN3 Protective Ground SPM Serial Port ERNI P N 284699 or 100503240001 8 poles PIN1 TX1 Transmit data output RS232 PIN2 RX1 Receive data input RS232 PIN3 GND PIN4 RTS Request To Send signal RS232 input PIN5 CTS Clear To Send signal RS232 ou...

Page 16: ...smit data output RS232 PIN9 MAN 1 MAN Active PIN10 RX6 Receive data input RS232 PIN11 5V PIN12 GND microUSB Connector PIN1 VBUS USB PIN2 DM PIN3 DP PIN4 ID PIN5 GND ETH LAN Ethernet 10 100MB RJ45 Green Led Indicate the network link OFF link off ON link on Yellow Led Indicate the flow of data Blink data flowing LL LED LINK Off Contactless reader not powered After the power on of the device the led ...

Page 17: ...ntents or to manufacture use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 17 RST RESET PUSHBUTTON Press to reset the device SAM2 SAM3 Dual SAM Connector Inside the Module SAM2 Connector Top Insertion on top SAM3 Connector Bottom Insertion on bottom D R A F T V 0 1 ...

Page 18: ...od N Q060R04 18 7 CABLE Following some examples of cables 7 1 CAC0096 POWER CABLE J1 Connector female ERNI IDC 3 Poles Black Friction Lock P N 101603240001 Cable Discrete Wire AWG 24 Length 50cm The pin 3 GROUND must be used for the grounding of the device 7 2 CAC0136 BV1000CL GBC SERIAL CABLE J1 Connector female ERNI IDC 12 Poles Black Friction Lock P N 101903240001 SP4 Connector SUB D 9 Poles Fe...

Page 19: ... use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 19 7 3 CAC0138 CABLE BV1000R BV1000CL J1 Connector female ERNI IDC 12 Poles Black Friction Lock P N 101903240001 J2 Connector female ERNI IDC 12 Poles Black Friction Lock P N 101903240001 Cable FLAT Wire AWG 26 Length 30cm D R A F ...

Page 20: ... contents or to manufacture use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 20 8 MECHANICAL DIMENSIONS 8 1 BV1000CL MECHANICAL DIMENSIONS FIGURE 2 Mechanical dimension of the BV1000CL Note Advised front label thickness 0 25mm 0 5mm plastic frame D R A F T V 0 1 ...

Page 21: ... not convey any rights to reproduce or disclose its contents or to manufacture use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 21 FIGURE 3 BV1000CL Fixing Screws Note Maximum fixing torque 1 7Nm D R A F T V 0 1 ...

Page 22: ...es not convey any rights to reproduce or disclose its contents or to manufacture use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 22 8 2 BV1000CL PANEL DRILLING FIGURE 4 Panel drilling BV1000CL D R A F T V 0 1 ...

Page 23: ...no Al Campo Varese Italy Tel 39 0331 904454 Fax 39 0331 901835 Internet www globalcom eng com e mail info globalcom eng com Globalcom Engineering pursues a policy of continued effort to improve the quality of its products and evidence published To this are constantly dedicated resources to ensure the accuracy of the information contained in the documents We will be grateful if you find missing inf...

Page 24: ... reproduce or disclose its contents or to manufacture use or sell anything it may describe Reproduction disclosure or use without specific written authorization of Globalcom Engineering is strictly forbidden Mod N Q060R04 24 Globalcom Engineering S p A Via Volta 39 21010 Cardano Al Campo Varese Italy Tel 39 0331 904454 Fax 39 0331 901835 D R A F T V 0 1 ...