background image

Summary of Contents for 5900652387823

Page 1: ...ja monta u i u ytkowania EN Operating and installation instructions DE Gebrauchs und Montageanleitung PL Okap kuchenny do zabudowy EN Built in range hood DE Einbau Dunstabzugshaube Hadario Hadario 60...

Page 2: ...U POD CZENIE ELEKTRYCZNE CZYSZCZENIE I KONSERWACJA FILTR W GLOWY FILTR PRZECIWT USZCZOWY STEROWANIE PRAC OKAPU CO ROBI W RAZIE NAPOTKANIA PROBLEMU ETYKIETA ENERGETYCZNA SPOSOBY ZMNIEJSZENIA WP YWU PRO...

Page 3: ...by m c z niej skorzysta w ka dej chwili Zesp GLOBALO Dla zapewnienia Pa stwu maksymalnego bezpiecze stwa w u ytkowaniu zakupionego urz dze nia najwa niejsze tre ci niniejszej instrukcji zosta y wyr ni...

Page 4: ...wo zapali Zasysane powietrze przez okap nie mo e by odprowadzane do kana u kominowego s u cego do odprowadzania spalin z urz dze spalaj cych gaz lub inne paliwo nie dotyczy to okap w z obiegiem zamkni...

Page 5: ...ektrycznego i elektronicznego oraz baterii Prowadz cy punkty zbi rki w tym lokalne punkty zbi rki sklepy oraz gminne jednostki tworz odpowiedni system umo liwiaj cy oddanie tego sprz tu oraz baterii j...

Page 6: ...E ZAGI K TY ZAGI NIE POWINNY BY WI K SZE NI 90 STOPNI NIE ZALECA SI STOSOWANIA ZMIAN PRZEKROJU PRZEWODU WI KSZEGO NA MNIEJSZY NP WYLOT POWIETRZA 15 CM NA WYLOT POWIETRZA 12 CM ZADBAJ ABY W POMIESZCZEN...

Page 7: ...trukcji obs ugi urz dzenia grzewczego podana jest wi ksza od leg o ni wskazana powy ej dostosuj si do takich wskaza Monta okapu przedstawiony jest na rysunkach Rys 5 Rys 12 W trakcie jego przeprowa dz...

Page 8: ...rej ma by zamontowany okap Je li nie jest to mo liwe zabezpiecz elementy znajduj ce si w pobli u wykonywanych prac Sprawd czy w pobli u strefy montowania okapu znajduje si gniazdko wtykowe i czy mo n...

Page 9: ...0 600 245 800 min 750 max 786 min 20 245 INSTALACJA OKAPU 1 Przygotuj szafk do monta u okapu wycinaj c otw r w spodzie szafki zgodnie z rysunkiem HADARIO 60 HADARIO 80 Rys 5 Rys 6 2 Wymontuj filtr alu...

Page 10: ...PL 3 Wsu okap we wcze niej wyci ty otw r przytrzymuj c okap jedn r k od do u lub popro o pomoc Zamocuj okap wybieraj c jeden wariant mocowania a mocowanie do p ki szafki Rys 7 wkr ty do drewna 4x16 x...

Page 11: ...y boczne nie s elementami zestawu Nale y je dobra w zale no ci od rozmiar w szafki Ich grubo mo na obliczy ze wzoru g D 550 2 mm g D 750 2 mm gdzie D to wewn trzna szeroko szafki a g to grubo listwy w...

Page 12: ...12 PL Rys 9 Rys 10 4 Zamontuj filtr przeciwt uszczowy 5 Pod cz rur do kr ca silnika...

Page 13: ...j agodne rodki myj ce Nie u ywaj rodk w ciernych Czyszczenie okapu wykonuj przynajmniej raz w miesi cu lub co 35 godzin pracy okapu Do mycia okapu w adnym wypadku NIE U YWAJ RODK W NA BAZIE ALKOHOLU E...

Page 14: ...sku powoduje w czenie turbiny okapu z minimaln pr dko ci wci ni cie przycisku powoduje w czenie turbiny okapu ze redni pr dko ci wci ni cie przycisku powoduje w czenie turbiny okapu z maksymaln pr dko...

Page 15: ...wnym je li jest starszy ni 6 miesi cy tylko przy trybie z zamkni tym obiegiem powietrza Sprawd czy ilo powietrza odbieranego z kuchni jest zr wnowa ona przez wystarczaj cy dop yw wie ego powietrza aby...

Page 16: ...wania na minimalny bieg kt ry pozwoli na usuni cie opar w przy aktualnej intensywno ci gotowania SERWIS Je eli pomimo naszej dok adnej kontroli jako ci stwierdz Pa stwo nieprawid owo ci w pracy i funk...

Page 17: ...g w okap nie reaguje na naciskanie p l sterowania Prawdopodobnie zawiesi si panel sterowania Nale y od czy okap od r d a zasilania na ok 15s i w czy go ponownie Turbina okapu wy cza si po 15min pracy...

Page 18: ...anie przewodu wentylacyjnego Powstanie widocznych uszkodze mechanicznych po monta u urz dzenia UWAGA TOWAR POSIADAJ CY USZKODZENIA MECHANICZNE KT RY MIMO TO ZOSTA ZAMONTOWANY NIE PODLEGA WYMIANIE PRZE...

Page 19: ...19 PL...

Page 20: ...ION BEFORE HOOD INSTALLATION HOOD INSTALLATION POWER SUPPLY CONNECTION CLEANING AND MAINTENANCE CARBON FILTER ANTI GREASE FILTER SETTINGS IN CASE OF PROBLEMS ENERGY LABEL REDUCING THE IMPACT OF COOKIN...

Page 21: ...ce so that you can consult it at any time GLOBALO team In order to ensure the maximum safety of the device the most important information has been marked with the following symbol THE CAUTION SYMBOL I...

Page 22: ...eep frying overheated fat can easily ignite The air sucked in by the hood must not be discharged into a flue pipe used for exhaust fumes from appliances burning gas or other fuels this does not apply...

Page 23: ...ectrical and electronic equipment and batteries if any to special collection points for such items Operators of collection facilities including local collection points shops and municipal units must h...

Page 24: ...DING OF THE DUCT SHOULD BE LIMITED TO MINIMUM THE ANGLES SHOULD NOT EXCEED 90 COMBINING DUCTS WITH DIFFERENT CROSS SECTIONS IS NOT RECOMMENDED E G 15 CM WITH 12 CM ENSURE THAT THE SIZE OF THE SUCTION...

Page 25: ...he cooker manual indicates a greater distance than specified above follow the instructions in the cooker manual Installation of the product is shown in Figures 5 12 During installation follow the gene...

Page 26: ...ele ments Check whether there is a socket near the hood installation space and whether it is possible to connect the hood to a ventilation duct for fume extraction Make sure there are no lines of elec...

Page 27: ...t where the hood is to be installed by cutting a hole in the bottom of the cabinet as shown in the figure Fig 5 2 Remove the aluminium anti grease filter Fig 6 min 550 max 586 min 20 600 245 800 min 7...

Page 28: ...hood into the pre cut hole holding the bottom of the exhaust hood with one hand or ask for help Fix the exhaust hood by choosing one of the mounting options a fixing to the shelf of a kitchen cupboard...

Page 29: ...the set They must be selected according to the size of the kitchen cupboard Their thickness can be calculated using the formula g D 550 2 mm g D 750 2 mm where D is the internal width of the kitchen c...

Page 30: ...30 EN Fig 9 Fig 10 4 Install the grease filter 5 Connect the duct to the motor connection...

Page 31: ...tergents for cleaning Do not use abrasive cleaning products The hood should be cleaned at least once a month or every 35 hours of operation DO NOT USE ALCOHOL BASED CLEANING AGENTS Inox parts should b...

Page 32: ...od turbine on at minimum speed pressing the button turns the hood turbine on at medium speed pressing the button turns the hood turbine on at maximum speed pressing the button turns the lighting on Pr...

Page 33: ...t of air extracted from the kitchen is balanced by sufficient fresh air supply to prevent negative pressure Check whether the ventilation chimney is not obstructed Excessively low atmospheric pressure...

Page 34: ...ssistance of our team The service support is available Monday to Friday from 9 00 am to 5 00 pm at 48 13 49 27 560 extension 3 and 48 609 055 660 or by email at serwis globalo pl Before connecting the...

Page 35: ...us sign for about 10 seconds or switch off the device Number 4 on the display is blinking and after 5 min the speed level changes to 3 The hood is equipped with a turbo mode which automatically change...

Page 36: ...anufacturer including without limitation uncon trolled power surge flooding obstruction of the ventilation duct Apparent mechanical damage after installation of the device CAUTION ANY PRODUCT WITH MEC...

Page 37: ......

Page 38: ...DUNSTABZUGSHAUBE ELEKTRISCHER ANSCHLUSS REINIGUNG UND WARTUNG KOHLEFILTER FETTFILTER STEUERUNG DER DUNSTABZUGSHAUBE WAS IST BEI PROBLEMEN ZU TUN ENERGIEETIKETT METHODEN ZUR REDUZIERUNG DER UMWELTEINWI...

Page 39: ...und Montageanleitung gut aufzubewahren damit Sie jederzeit auf sie zugreifen k nnen GLOBALO Team Um Ihnen maximale Sicherheit bei Gebrauch des von Ihnen gekauften Ger tes zu gew hrleisten sind die wic...

Page 40: ...gshaube angesaugte Luft darf nicht in die Abgasleitung ber die bei der Verbrennung von Gas oder anderen Brennstoffen erzeugte Abgase abgeleitet werden eingeleitet dies gilt nicht f r Dunstabzugshauben...

Page 41: ...rische und elektronische Ger te und Batterien zu bergeben Die Betreiber von Abfallssammelstellen darunter auch von lokalen Abfallssammelstellen Gesch ften und kommunalen Abfallssammelstellen bilden ei...

Page 42: ...AD BETRAGEN ES WIRD NICHT EMPFOHLEN VON EINEM LEITUNGSDURCHMESSER IN EINEN ANDEREN ZU WECH SELN VON EINEM H HEREN DURCHMESSER IN EINEN GERINGEREN DURCHMESSER Z B VON EINEM LUFTAUSLAUF 15 CM IN EINEN L...

Page 43: ...t in der Gebrauchsanleitung des jeweiligen Herdes ein Abstand angegeben der h her als der hier genannter Abstand ist ber cksichtigen Sie solche Vorgaben Die Dunstabzugshaubemontage ist auf den Abbildu...

Page 44: ...en Gegenst nde Pr fen Sie ob in der N he der Dunstabzugshaubemontagezone eine Steckdose vorhanden ist und ob die Dunstabzugshaube an eine L ftungsleitung die D nste nach au en ableitet ange schlossen...

Page 45: ...einen Schrank zur Montage der Dunstabzugshaube indem Sie gem der Zeich nung eine Bohrung im Schrankboden herstellen Abb 5 2 Bauen Sie den Aluminium Fettfilter aus Abb 6 min 550 max 586 min 20 600 245...

Page 46: ...te ffnung wobei Sie die Abzugshaube mit einer Hand halten oder bitten Sie jemanden dass er Ihnen dabei hilft Befestigen Sie die Abzugshaube indem Sie eine der Befestigungsvarianten w hlen a Befestigun...

Page 47: ...liche leisten werden mit dem Set nicht mitgeliefert Sie sind je nach w Schrankma en anzupassen Ihre St rke kann man nach folgender For mel errechnen g D 550 2 mm g D 750 2 mm wobei D innere Schranksei...

Page 48: ...48 DE 4 Den Fettfilter einsetzen 5 Verbinden Sie das Rohr mit dem Motorstutzen Abb 9 Abb 10...

Page 49: ...enden Sie keine Schleifmittel Reinigen Sie die Dunstabzugshaube zumindest einmal im Monat oder immer nach 35 Betriebsstunden Zur Reinigung der Dunstabzugshaube VERWENDEN SIE AUF KEINEN FALL REINIGUNGS...

Page 50: ...en Ein Filter welches nicht regelm ig gereinigt wird verringert die Leistung der Dunstabzugshaube und kann auch dazu beitragen dass ein Brand entsteht Durch Dr cken der Taste wird die Turbine der Abzu...

Page 51: ...sleitung vorhanden sind Pr fen Sie ob sich in dem L ftungskanal die R ckzugklappe nicht festklemmt falls eine solche R ckzugklappe optional eingebaut ist Ist der L ftungskanal mit einem Pendelgitter a...

Page 52: ...llen Sie trotz unserer sorgf ltigen Qualit tskontrolle Unregelm igkeiten im Betrieb des von Ihnen gekauften Ger tes fest wenden Sie sich bitte an unsere Serviceabteilung wo Sie jederzeit professionell...

Page 53: ...keitsstufen angezeigt die Dunstabzugshaube reagiert nicht wenn die Steuerungsschaltfl chen bet tigt werden Voraussichtlich ist das Bedienfeld abgest rzt Die Dunstabzugshaube ist f r ca 15 Sekunden vom...

Page 54: ...ur von Fehlern die eindeutig auf Herstellungsfehler zur ckzuf hren sind Ausge schlossen von der Garantie sind Gl hbirnen Sicherungen und Filter sowie alle Arten von Sch den die durch unsachgem e Monta...

Page 55: ...EN ZU IDENTIFIZIEREN GEW HRLEISTUNGSANSPR CHE DIE SICH AUF SICHTBARE USSERE SCH DEN BEZIEHEN DIE NACH MONTAGE BEANSTANDET WERDEN SIND AUCH AUSGESCHLOSSEN GLOBALO MAX BERNIMMT KEINE HAFTUNG F R SCH DEN...

Page 56: ...UP Sp z o o ul Mak w 10 38 500 Sanok Polska Poland Polen Tel 48 13 49 27 560 Fax 48 13 49 27 580 https globalo pl e mail biuro globalo pl Serwis Service Kundendienst Tel 48 13 49 27 560 wew 3 Kom 48 6...

Reviews: