66468

The  efficiency  of  this  product  has  been  scientifically  tested  in  a  lab  against  the  following 

bacteria; Staphylococcus Aureus (ATCC6538), Escherichia Coli (10389), Salmonella 

Typhimurium (ATCC14028), and influenza. To increase the level of neutralization, place the 

work light from the item/surface at the minimal recommended distance for a longer period. 

Products will still be effective when distance is increased but will require a longer exposure to 

the UV light to neutralize germs. When used as directed, the following results will be obtained 

at the given distance and time:  

A) Optimal Use

For maximum disinfection (99.9%), the light should 

be placed 1 foot (0.3m) away from the surface for 

one 30 minute cycle for bacteria or placed at 6” 

(15.25cm) for one 30 minute cycle for influenza.  

B) Optional Use (recommended for bacteria only)

When the light is placed at 2 feet (0.6m) for 

30 minutes, the percentage of antibacterial 

neutralization should reach over 70% depending on 

the surface conditions. Repeat 30 minute cycle to 

increase effectiveness.  

BATTERY – To charge the lamp. Plug the included USB charging cable to the standard 5V 

charger.
• The indicator will be red when charging. 

• When the battery is fully charged, at around 1.5 hours, the indicator will turn off.        

• Once fully charged, the lamp will have 2.5 hour battery life.      

 

 

TO MAXIMIZE THE EFFECTIVENESS OF YOUR UVC DEVICE

RECHARGING THE LAMP

5v

Summary of Contents for 66468

Page 1: ...encounter any difficulties have any questions or simply wish to offer us your valuable feedback you may contact us in the following ways Toll Free Telephone 1 888 543 1388 North America Only Toll Free...

Page 2: ...s a wavelength shorter than that of visible light and is generally subdivided into UV A UV B and UV C While Near UV is not technically within the ultraviolet spectrum it shares certain useful germicid...

Page 3: ...and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Page 4: ...ww globe electric com CAN ICES 005 B CAN NMB 005 B TECHNICAL DATA 1 Model 66468 2 UV C Quartz Wave Technology 254nm 3 Power 2 5 W 4 Life Span 10 000 hours 5 Rechargeable 3 7V 800mAh battery 6 30 Secon...

Page 5: ...or maximum disinfection 99 9 the light should be placed 1 foot 0 3m away from the surface for one 30 minute cycle for bacteria or placed at 6 15 25cm for one 30 minute cycle for influenza B Optional U...

Page 6: ...To maximize the effectiveness of the product surfaces should be relatively clean and free of grime dust and other materials that will prevent the germs from being directly exposed to UV C Light 1 Stan...

Page 7: ...amages including but not limited to any loss of business or profits whether foreseeable or not Some jurisdictions may not all the exclusion of incidental consequential damages so the above limitation...

Page 8: ...1 003 20 Please see our website to learn more about UV technology or for any further directional use of any products in the Globe Electric UV assortment line globe electric com en uv light ADDITIONAL...

Page 9: ...Visite nuestra p gina web para conocer m s acerca de cualquier producto de la gama UV C de Globe Electric globe electric com en uv light ASISTENCIA ADICIONAL 66468...

Page 10: ...de negocios o ingresos ya sea previsible o no Algunas jurisdicciones podr an no permitir la exclusi n de da os incidentales o consecuentes de manera que la limitaci n o exclusi n anterior podr a no s...

Page 11: ...ra maximizar la eficacia del producto las superficies deben estar relativamente limpias y libres de suciedad polvo y otros materiales que impidan que los g rmenes queden expuestos directamente a la lu...

Page 12: ...0 3 m 1 ft de la superficie durante un ciclo de 30 minutos para eliminar bacterias o a 15 25 cm 6 in durante un ciclo de 30 minutos para eliminar el virus de la gripe B Uso opcional recomendado nicame...

Page 13: ...5 B CAN NMB 005 B DATOS T CNICOS DIMENSIONES DEL PRODUCTO 2 52 x 2 52 x 5 83 6 40cm x 6 40cm x 14 80cm 1 Modelo 66468 2 Tecnolog a UV C Quartz Wave 254nm 3 Energ a 2 5 W 4 Vida til 10 000 horas 5 Bate...

Page 14: ...uipo se recomienda al usuario intentar corregir la interferencia mediante una o m s de las siguientes medidas Reoriente o reubique la antena receptora Aumente la separaci n entre el equipo y el recept...

Page 15: ...isible para el ojo humano llamado ultravioleta La luz ultravioleta tiene una longitud de onda m s corta que la luz visible y en general se subdivide en UV A UV B y UV C Aunque la UV cercana no est t c...

Page 16: ...una pregunta o simplemente desea ofrecernos sus valiosos comentarios puede ponerse en contacto con nosotros de las siguientes maneras Llamadas sin costo 1 888 543 1388 solo en Norteam rica Fax sin co...

Reviews:

Related manuals for 66468