background image

 Rev. -         02/23/2015           995095 Gas Conversion Manual Griddle

Gas Griddle 

(Manually Controlled)

Conversion Kit Instructions

Do not attempt gas conversion by yourself. Gas conversion of your unit is to be 

made by a certified/licensed technician. Locate an authorized Globe servicer at 

www.globefoodequip.com

CONVERSION

Instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion should be 

done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on 

natural gas. Parts necessary for L.P. (liquid propane) are provided with the unit. 

Turn off the main gas supply 

before doing any maintenance.

1.   Remove the knobs and front panel.

2.   Unscrew bolts and pilot valve, then  

      remove the manifold.

3.   Replace the orifice fittings into the valve.

      

Note: 

Unit Number on side of orifice

      fittings.

4. Replace the front panel and knobs.

5. Before installing the included convertible 

    regulator, unscrew the octagon cap. You can read 

    (NAT) on the plastic insert attached to the head of  

    the cap; flip it over and snap back in place.

Convertible 

regulator with 

octagon cap. 

Unscrew from 

regulator.

Pull off 

plastic insert 

from octagon 

cap and 

reverse the 

plastic insert 

position so 

that the L.P. 

position is 

attached to 

the octagon 

cap head.

L.P. Position 

of insert. 

Regulator 

is now 

converted to 

L.P.

6. Continue with installation.

L.P.

L.P. Position

NAT

L.P.

Pg 2 of 4

CAUTION FOR SERVICERS: 

If you convert from one gas type to another, please adjust to the correct gas 

pressure before use. Also, be sure to indicate the correct gas markings on all equipment tags/lables. 