Solution:
Check whether the machine chuck is loosened, whether the tool ring on the
tool is installed in place, or the tool library is damaged.
5)
The warning message show
error there is tool on the spindle
Alarm reason
: There is a tool on the spindle when the it begin to detect the tool;
Solution:
If there is no tool in the spindle, but the tool number is displayed incorrectly,
click the
[CLAMP]
button on the control panel, and the current tool number will be
automatically cleared; if there is a tool on the spindle, click the
[CLAMP]
button on
the control panel and take it manually the tool on the spindle,then returned to the
corresponding tool library, and the current tool number is automatically cleared.
6)
The warning message show
error the spindle must not be clampe tool before the
program is run
Alarm reason:
The current tool number is not 0, and processing cannot be started;
Solution:
Turn off the alarm message, reset the machine, press the
[CLAMP]
button
to remove the toolr on the spindle and put it back into the corresponding tool library,
and restart processing.
7)
The warning message show
CPU State=SIMULATION
Alarm reason:
The program is running in the simulation mode, the machine does not
return to the origin when the machine is turned on, and the file cannot be read (the
prompt can be seen by pulling the prompt page to the top third line), indicating that
the machine computer is not connected to the machine motherboard.
Solution:
Copy the cnc.ini and macro.cnc files in the C drive to the WhitethCNC
folder to overwrite the original files, restart DentalMill, if the alarm still occurs, check
whether the USB connection or network cable connection between the computer and
the control board is not contact well, If the wire is damaged, it needs to be replaced;
after removing the above, check whether the computer and control board are damaged
and need to be replaced.
8)
The warning message show
ESTOP active, please reset
Alarm reason:
Air pressure alarm;
Solution:
Turn off the alarm message after the air pressure returns to normal, and then
reset it.
9)
The warning message show
EXTERR IN active, please reset.
Alarm reason:
Driver alarm;
Solution:
Shut down and check whether the five-axis motor of xyzab and the spindle
inverter wire and the connection between them are in poor contact, whether they are
damaged and need to be replaced; or whether the five-axis motor of xyzab is smooth
and not stuck, and whether the spindle rotates flexibly.