46
Diagram 13.13
13.5 Condense Trap and Siphonic Drain
The condense trap and siphonic drain does not normally need
servicing unless material deposits exceed beyond the service
fill level, see diagram 13.13.
To clean the condense trap remove the sump and rinse with
water.
13.6 Casing panel seal check
NOTE: If the functional checks did not indicate poor
combustion then it is not necessary to service this
component.
Check the condition of the seal and replace if worn or
damaged.
To replace remove the old seal and thoroughly clean the
casing surfaces. Fit the new seals, these are supplied to the
correct lengths and are in four pieces, for use on the sides,
top and bottom.
13.7 Service Completion
Re-check the combustion as described at the beginning of
this section.
On completion of the service the “Benchmark” Service Record
should be completed.
13 Servicing
CONDENSE TRAP
AND SIPHONIC DRAIN
SERVICE
FILL LEVEL
SECURING
SCREW
SUMP
13929
SECURING
NUTS (6)
BURNER
FAN CLAMPING
BRACKET
Diagram 13.12
14410
14397