0020313973_01 Compact Installation and maintenance instructions
7
3
Technical data
Technical data
–
General
24c-AS/1 (H-GB)
28c-AS/1 (H-GB)
Designated country (designation in accordance with ISO 3166)
GB, IE
GB, IE
Permissible gas categories
ll2H3P
ll2H3P
CE number
0063CU3005
0063CU3005
ErP
92 %
93 %
Product-side gas connection
1/2"
1/2"
Product-side flow/return heating connections
3/4"
3/4"
Expansion relief valve connection pipe (min.)
15 mm
15 mm
Condensate discharge hose (min.)
14.2 mm
14.2 mm
Gas connection pressure, G20 natural gas
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
Gas connection pressure, liquefied petroleum gas G31
3.7 kPa
(37.0 mbar)
3.7 kPa
(37.0 mbar)
Maximum flue gas temperature
89
℃
89
℃
Min. gas volume flow at 15 °C and 1013 mbar, G20
0.66 m
³
/h
0.76 m
³
/h
Min. gas volume flow at 15 °C and 1013 mbar, G31
0.65 kg/h
0.56 kg/h
Max. gas volume flow at 15 °C and 1013 mbar (based on heating mode), G20
1.99 m
³
/h
2.59 m
³
/h
Max. gas volume flow at 15 °C and 1013 mbar (based on heating mode), G31
1.47 kg/h
1.91 kg/h
Max. gas volume flow at 15 °C and 1013 mbar (based on domestic hot water
generation), G20
2.54 m
³
/h
2.96 m
³
/h
Max. gas volume flow at 15 °C and 1013 mbar (based on domestic hot water
generation), G31
1.86 kg/h
2.18 kg/h
Permissible installation types
C13, C33, C43, C53
C13, C33, C43, C53
Nominal efficiency in partial load mode (30%)
107.8 %
108.2 %
NOx class
6
6
Nitrogen oxide emissions, NOx weighted (Hs) (G20)
27.11 mg/kW
⋅
h
32.40 mg/kW
⋅
h
CO emissions
137.2 ppm
121.7 ppm
Net weight
25.6 kg
26.5 kg
24c-AS/1 (P-GB)
28c-AS/1 (P-GB)
Designated country (designation in accordance with ISO 3166)
GB, IE
GB, IE
Permissible gas categories
ll2H3P
ll2H3P
CE number
0063CU3005
0063CU3005
ErP
91 %
92 %
Product-side gas connection
1/2"
1/2"
Product-side flow/return heating connections
3/4"
3/4"
Expansion relief valve connection pipe (min.)
15 mm
15 mm
Condensate discharge hose (min.)
14.2 mm
14.2 mm
Gas connection pressure, G20 natural gas
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
Gas connection pressure, liquefied petroleum gas G31
3.7 kPa
(37.0 mbar)
3.7 kPa
(37.0 mbar)
Maximum flue gas temperature
89
℃
89
℃
Min. gas volume flow at 15 °C and 1013 mbar, G20
0.66 m
³
/h
0.76 m
³
/h
Min. gas volume flow at 15 °C and 1013 mbar, G31
0.65 kg/h
0.56 kg/h
Max. gas volume flow at 15 °C and 1013 mbar (based on heating mode), G20
1.99 m
³
/h
2.59 m
³
/h
Max. gas volume flow at 15 °C and 1013 mbar (based on heating mode), G31
1.47 kg/h
1.91 kg/h
Max. gas volume flow at 15 °C and 1013 mbar (based on domestic hot water
generation), G20
2.54 m
³
/h
2.96 m
³
/h
Max. gas volume flow at 15 °C and 1013 mbar (based on domestic hot water
generation), G31
1.86 kg/h
2.18 kg/h
Permissible installation types
C13, C33, C43, C53
C13, C33, C43, C53
Summary of Contents for Compact 24c-AS/1
Page 59: ......