Installation and maintenance instructions EASICOM 3 0020239562_04
2.
Remove the volume flow sensor
(1)
.
3.
Install the new volume flow sensor.
4.
Plug in the plug.
13.6.11 Replace the pressure sensor
1
2
1.
Pull out the plug.
2.
Remove the clip
(1)
.
3.
Remove the pressure sensor
(2)
.
4.
Install the new pressure sensor.
5.
Reattach the clip
(1)
.
13.7
Checking the product for leak-tightness
▶
Check that the product is leak-tight. (
14 Decommissioning the product
▶
Decommission the product.
▶
Disconnect the product from the power grid.
▶
Close the gas stopcock.
▶
Close the cold-water stopcock.
▶
Drain the product. (
15 Recycling and disposal
Disposing of the packaging
▶
Dispose of the packaging correctly.
▶
Observe all relevant regulations.
▶