Appendix
36
Installation and maintenance instructions Energy 0020201109_01
I
Technical data
Technical data
–
Heating
Energy 35 Store-A
Max. range of the flow temperature
control
10 … 80
℃
Maximum permissible pressure (PMS)
0.3 MPa
(3.0 bar)
Maximum heat output (P max.), set at
the factory
30 kW
Water flow at P max., set at the factory
(
Δ
T = 20 K)
1,292 l/h
Δ
P heating at P max., set at the factory
(
Δ
T = 20 K)
39.8 kPa
(398.0 mbar)
Approximate value for the condensate
volume (pH value between 3.5 and 4.0)
at 50/30 °C
3.18 l/h
Technical data
–
G20
Energy 35 Store-A
Effective output range (P) at 50/30 °C
9.3 … 32.5 kW
Effective output range (P) at 80/60 °C
8.5 … 30.0 kW
Hot water heat output range (P)
8.7 … 35.7 kW
Maximum heat input
–
heating (Q max.)
30.6 kW
Minimum heat input
–
heating (Q min.)
8.7 kW
Maximum heat input
–
hot water (Q
max.)
35.7 kW
Minimum heat input
–
hot water (Q
min.)
8.7 kW
Technical data
–
G31
Energy 35 Store-A
Effective output range (P) at 50/30 °C
8.8 … 31.9 kW
Effective output range (P) at 80/60 °C
8.5 … 30.0 kW
Hot water heat output range (P)
8.7 … 35.7 kW
Maximum heat input
–
heating (Q max.)
30.6 kW
Minimum heat input
–
heating (Q min.)
8.7 kW
Maximum heat input
–
hot water (Q
max.)
35.7 kW
Minimum heat input
–
hot water (Q
min.)
8.7 kW
Technical data
–
Domestic hot water
Energy 35 Store-A
Minimum water flow
0.1 l/min
Specific flow rate (D) (
Δ
T = 30 K) in ac-
cordance with EN 13203
23.0 l/min
Maximum permissible pressure (PMW)
1 MPa
(10 bar)
Temperature range
45 … 65
℃
Cylinder capacity
42.0 l
Technical data
–
General
Energy 35 Store-A
Gas category
II2H3P
Diameter of the gas pipe
1/2"