background image

 

 

 

 

Document revisions 

 

Revision number 

Notes 

Date released 

20220607-1 

Santinel WiFi and Santinel Cellular pairing 
procedures updated. 
Covers firmware V. 1.0.0 

06/2022 

20210909-1 

First version available. 
Covers firmware V. 1.0.0 

09/2021 

 
 
 
 
 
 
 
 
 
 

GLP® Santinel WiFi / Cellular - Hand Disinfecting Station User Manual 

 

© 2020-22 German Light Products GmbH. All rights reserved. 

The marks ‘GLP’ and ‘German Light Products’ are trademarks registered as the property of German 

Light Products GmbH in Germany, in the United States of America and in other countries. 

The information contained in this document is subject to change without notice. German Light 
Products GmbH and all affiliated companies disclaim liability for any injury, damage, direct or 
indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to 
use or reliance on the information contained in this document. 
Head office: 
German Light Products GmbH (GLP), Industriestrasse 2, 76307 Karlsbad, Germany 
Tel (Germany): +49  7248  92719 - 0 
Service & Support EMEA: 
GLP, Industriestrasse 2, 76307 Karlsbad, Germany 
Tel. (Germany): +49  7248  9271955 
Email: support@glp.de 
www.glp.de 

Service & Support USA: 
GLP USA, 1145 Arroyo St., Ste. A, 91340 San Fernando, California 
Tel (USA): +1  818  767  8899 
Support (US): info@germanlightproducts.com 
www.germanlightproducts.com 

 

Summary of Contents for Santinel Cellular

Page 1: ...Santinel WiFi Santinel Cellular Hand Disinfecting Station User Manual User Manual Rev 20220607 1 Firmware V 1 0 0...

Page 2: ...contained in this document is subject to change without notice German Light Products GmbH and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or...

Page 3: ...e 9 Physical installation 9 Installing batteries 11 Connecting to mains power 12 4 Using the Santinel 13 Switching on and off 13 Disinfecting hands 13 5 Control panel 15 Control buttons 15 LCD display...

Page 4: ...microbial and viral infection via the hands To protect from infection in shared spaces in the presence of customer traffic at events in public institutions and in similar applications Contraindication...

Page 5: ...w around the product Do not allow children to use the product unsupervised Fire safety The disinfectant has a low flash point of around 23 C 73 4 F and is therefore highly inflammable Do not allow the...

Page 6: ...ry give him something sweet to keep the blood sugar from dropping In any case call medical assistance If you need to transfer disinfectant from one container to another do so under aseptic conditions...

Page 7: ...on on left hand side of housing D Dispensing area E Access flap lock and handle F Mains power cable G Drip tray H Disinfectant fluid container I Container cap with fluid hose connector J Fuse holder K...

Page 8: ...fluid container and all sensitive components are hidden under a tamper proof locking service flap where there is also a 4 button control panel that works together with the LCD display on the front of...

Page 9: ...sed See Figure 2 To open the power cable storage compartment if you need to remove or insert the power cable remove the two screws arrowed in the compartment door Close the door and reinstall the two...

Page 10: ...base of the Santinel and turn each fastener a full 90 clockwise to lock it 3 Make sure that the Santinel is held securely Make sure that the fasteners are not accessible to unauthorized persons Mounti...

Page 11: ...milar strength material 4 See Figure 5 Hang the Santinel on the bracket by passing the two cutouts arrowed in the rear of the Santinel housing over the hooks in the bracket and lowering the Santinel u...

Page 12: ...is rated minimum 250 V 16 A that it has a connection to ground earth and that it has an integral cable grip 2 Cut the existing Schuko type plug off the power cable 3 To install the new mains plug cor...

Page 13: ...ant If you are operating the Santinel on battery power we recommend that you always put the Santinel into standby mode when it is not being used To put the Santinel into standby mode press and hold th...

Page 14: ...ay on the front of the Santinel shows a smiley icon The disinfecting area lights up with a green light as a signal to the user to remove their hands When the user has removed their hands the Santinel...

Page 15: ...to use the control panel open the flap and Press MENU BACK once to call up the following information in the display Volume amount per disinfection process Dispensing volume approx total amount of disi...

Page 16: ...work LTE and the signal strength is excellent The rest of the display shows the control menus In Figure 8 the Santinel is showing the main information display that is called up with one press on MENU...

Page 17: ...airing control menu and start the pairing process The Santinel web interface and smartphone app chapter on page 19 explains these procedures in detail Standby Button Enable or disabling the standby bu...

Page 18: ...stom configuration settings and return the Santinel to factory settings press and hold ENTER for 3 seconds or if you do not want to return to factory settings press MENU BACK to cancel and escape Info...

Page 19: ...e If your Santinel does not already have the correct module installed GLP can convert it by installing the module Your GLP supplier will be happy to give you details WiFi configuration The Santinel Wi...

Page 20: ...evice with a Santinel account using account pairing To do this 1 Connect the Santinel to the Internet when a Santinel WiFi or Santinel Cellular is powered on it looks for a WiFi signal or cellphone si...

Page 21: ...Pull the tube connector vertically upwards to remove it from the connector stub on top of the disinfectant container 3 Lift the empty container vertically up and out of the Santinel making sure that n...

Page 22: ...close and lock the top flap 11 Take the sealed lid that was on the new container and screw it onto the old empty container Recycle or dispose of the empty container properly If in doubt about where t...

Page 23: ...s not dispensing disinfectant in order to save energy B Ambient Light The Santinel dispenses fluid The disinfectant area ambient lighting and the WiFi cellular module are enabled while the Santinel is...

Page 24: ...Factory Settings Confirm with ENTER To return the Santinel to factory settings press and hold ENTER for 3 seconds To cancel and escape press BACK Information Show Information Firmware Main Controller...

Page 25: ...ectant fluid carefully WARNING Any service operation that requires removal of a cover must be performed by a professional service technician with the necessary tools skills qualifications and personal...

Page 26: ...hould now be free and the Santinel should work normally again Important Do not turn the nozzle too far or it may come off and expose the sealing mechanism If this happens reassemble it carefully and r...

Page 27: ...e drip tray and put it back into position in the Santinel Leaking or defective disinfectant container or hose Disconnect the Santinel from power Check if the leakage is coming from the container or th...

Page 28: ...of disinfection processes Number of disinfection processes remaining for current disinfectant fluid container Construction Housing color Silver black other colors on request Housing material Hygienic...

Page 29: ...12 W 0 110 A Standby power 230 V 3 2 W 0 035 A Thermal Ambient temperature operating range From 5 C 40 F to 45 C 115 F Dimensions and weight Santinel Height 453 mm 17 9 in Width 250 mm 9 9 in Depth 30...

Page 30: ...www glp de GLP Santinel User Manual 30 12 Dimensions...

Page 31: ...Base Access flap...

Page 32: ...Wall Mount Plate...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ......

Reviews: