Electrical specifications
$
The electrical installation must conform to local regulations and guidelines.
"
The required cable/plug is usually not delivered with the processor.
#
Please be aware of double pole/neutral fusing.
#
The processor is Class 1 equipment. It must therefore be connected to earth to
avoid electrical shocks.
$
The fuses must have a breaking capacity of min. 100 kA. If using automatic
circuit breakers, make sure they are Type D.
When selecting a cable type take the following into account:
•
Chemical resistance:
Chemicals may leak onto cable
•
Mechanical resistance:
The operator may step onto cable.
•
Additional protection:
Provide for additional cable protection, e.g. cable covers, if
cable is exposed to heavier transport such as forklift trucks etc.
$
The conductors in the power supply cable must be of copper.