Warning.
The air filter must be added before first use.
Failure to fit the air filter will damage the compressor and
will void the warranty.
4. Remove the plastic air filter plug from the head of the
compressor.
5. Carefully screw the air filter assembly (16) into the
threaded hole taking care not to cross the thread.
6. Tighten firmly by hand only.
Pre-start routine
1. Ensure that the location for the compressor is clean,
dry and well ventilated.
2. Ensure the crank case has been filled with oil and is at
the correct level, and the air filter has been fitted.
3. Open the direct output valve (4) and the regulated
output valve (7).
Open the valve by sliding the outer sleeve fully forward.
To close the valve, slide the outer sleeve backward
towards the compressor.
4. Start the compressor by following the procedure in the
section “To start and stop the compressor”. For the first
time of operation, run the compressor for 10 min with
no load to ensure all parts are well lubricated.
Warning.
Be aware that presurised air will be discharged
from the two outlets and care should be taken that this
discharge is not directed towards you the operator, or
other persons within the area.
To start & stop the compressor
1. Check the rating label on
the compressor indicates
230V–240V.
2. Plug in the mains cable of
the compressor to a
standard 240V houshold
power point and turn on.
3. To start the compressor,
lift the On/Off switch (3)
on the pressure switch
cover (2).
4. To stop the compressor,
push the On/Off switch
(3) down.
11