background image

3

Do not switch on 

for the first time 

without first 

filling with oil.

��������

��������

Air discharged from 

this unit is not 

suitable for human 

consumption.

��������

Test the safety relief 

valve daily.

Refer the instruction 

manual.

���������

Keep oil level as shown:

Use only oil grade 

specified in instruction 

manual.

����������

To prevent build-up of 

condensation, open 

drain cock daily

When filter becomes 
dirty or oily, clean or 

replace filter. Refer to 

instruction manual.

����������������

�������

High voltage used on 

this equipment. Switch 

off power supply & 

remove plug from mains 

before removing any 

covers. Ensure mains 

outlet is adequately 

rated for this unit.

��������

��������

Unit starts 

automatically. 

Switch off power supply, 

remove plug & relieve 

air pressure prior to 

commencing service 

tasks.

���������

Read instruction manual 

prior to starting unit.

This equipment 

operates from 

AC mains only.

Warning labels explained

On the tank of your air compressor you will notice various 

warnings about the operation of the compressor. These 

warnings and the procedures associated with them are 

explained fully in this manual on the following pages. 

Please take note of these. They are important for your 

safety and that of others in the vicinity.

Summary of Contents for EAC30

Page 1: ...n consumption Test the safety relief valve daily Refer the instruction manual evel as shown nly oil grade d in instruction manual To prevent build up of condensation open drain cock daily When filter becomes dirty or oily clean or replace filter Refer to instruction manual ltage used on pment Switch wer supply lug from mains removing any Ensure mains s adequately for this unit ...

Page 2: ...nus items or included accessories Only the power tool is covered under this warranty With continuing product development changes may have occurred which render the product received slightly different to that shown in this instruction manual Please ensure that you store your receipt in a safe place Conditions apply to the above warranty For full details of the warranty terms and conditions please r...

Page 3: ...ff power supply remove plug from mains before removing any covers Ensure mains outlet is adequately rated for this unit Unit starts automatically Switch off power supply remove plug relieve air pressure prior to commencing service tasks Read instruction manual prior to starting unit This equipment operates from AC mains only Warning labels explained On the tank of your air compressor you will noti...

Page 4: ... 4 CFM Pump displacement 206 l min 216 l min 7 2CFM 7 65CFM Introduction Your new GMC power tool will more than satisfy your expectations It has been manufactured under stringent GMC Quality Standards to meet superior performance criteria You will find your new tool easy and safe to operate and with proper care it will give you many years of dependable service CAUTION Carefully read through this e...

Page 5: ...a heavier duty tool Never use a tool for a purpose for which it was not intended 7 Dress correctly Do not wear loose clothing or jewellery They can be caught in moving parts Rubber gloves and non slip footwear are recommended when working outdoors If you have long hair wear a protective hair covering 8 Use safety accessories Safety glasses and earmuffs should always be worn A face or dust mask is ...

Page 6: ...essor in a well ventilated area Do not smoke while spraying Do not spray where sparks or flames are present Keep the compressor as far away from the spray area as possible The solvents trichloroethane and methylene chloride can chemically react with the aluminium used in some paint spray guns and form an explosion If these solvents are used ensure that only stainless steel spray equipment is conne...

Page 7: ...e safety equipment including safety goggles or shield ear protection breathing or respirator mask and protective clothing Wear goggles Wear earmuffs Wear a breathing mask Never apply the outlet air of this compressor directly on to any part of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any u...

Page 8: ...ting knob 6 Regulated air outlet 7 Regulated outlet pressure gauge 8 Safety valve 9 Non return valve 10 Drain cock 11 Air tank 12 Wheel x 2 13 Safety cover 14 Oil filling plug 15 Air filter assembly 16 Oil level glass 17 Oil drain plug not shown 18 Air tap 14 8 1 2 3 5 9 6 4 7 10 15 13 16 11 12 18 14 ...

Page 9: ...l Rubber feet Fit the rubber feet on the bracket on the front underside of the tank using the screws washers and nuts supplied Oil WARNING The air compressor must be filled with oil before first use To prevent possible spillage of oil during transport the compressor oil is supplied in a separate container It must be added to the compressor before turning the compressor on Failure to add the oil wi...

Page 10: ... and the air filter has been fitted 3 Open the regulated output valve 6 Open the valve by rotating the air tap 18 so it is in line with the air outlet refer to the OPEN picture To close the valve rotate the air tap so it is facing to the right or the left side of the air valve refer to the CLOSED picture 4 Start the compressor by following the procedure in the section To start and stop the compres...

Page 11: ... the correct pressure while air is being discharged from the outlet 5 On completion of the task i e when you have finished using the compressor or when you are leaving the compressor unattended turn off the compressor in the following way Press down the on off switch 3 Wait for the pressurised air to bleed from the release valve under the pressure switch cover 2 Note When you press the button down...

Page 12: ... service centre to repair or replace faulty parts Main compressor sticking tight Moving parts damaged by heat due to insufficient lubrication Use authorised service centre to check crankshaft bearings con rod piston rings etc and replace where necessary Moving parts damaged or blocked by foreign particle Vibration or abnormal noise Loose part Use authorised service centre to check and repair if ne...

Page 13: ...authorised service centre to check and repair if necessary Damaged gasket Use authorised service centre to check and repair if necessary Damaged or carbon coated valve seat Use authorised service centre to check and repair if necessary Damaged piston ring or cylinder Use authorised service centre to check and repair if necessary Excessive oil consumption Oil level too high Maintain the oil at the ...

Page 14: ...e when performing this test as air will discharge from the valve at a high force If the safety valve does not operate correctly in any way as described above turn off the compressor immediately and have the compressor and safety valve checked and tested at an authorised Service centre DO NOT CONTINUE TO USE THE COMPRESSOR IN ANY WAY IF THE SAFETY VALVE DOES NOT WORK AS ABOVE General inspection 1 R...

Page 15: ...15 ...

Page 16: ...ew Zealand 7am 7pm 7days a week AEST Please note that if repair or replacement is required you must provide a valid original purchase receipt You will need the following details at hand to log your service request Personal details First Last name address pick up address contact phone numbers email address Product details Product number date of purchase retailer bought from State postcode receipt n...

Reviews: