Page 12
1OP1
0
30 – February 2018
Operating Instructions & Function Tests
Test Up/Down Functions
Check the area above and around the machine for obstructions and electrical power lines before
operating the machine.
The descent alarm sounds at
a continuous beep until the lower button or switch is released.
7 At the Lower Controls station, turn the Key Switch to off or platform position.
8 At the Lower Controls station, push up and hold the platform up / down switch.
• Result: No function should operate.
9 Turn the Key Switch to ground control position.
10 At the Lower Controls station, push up and hold the Platform Up switch.
• Result: The platform should raise.
11 Push down and hold the Platform Down switch.
• Result: The platform should lower to end. The descent alarm should sound
.
Test the Emergency Lowering
12 Activate the up function and raise the platform approximately 2 ft / 60 cm.
13 Pull the Emergency Lowering Knob.
• Result: The platform should lower. The descent alarm will not sound.
At the Platform Controls
14 Turn the Key Switch to platform control.
Test Emergency Stop
15 Push in the platform red Emergency Stop button to the off position.
• Result: No functions should operate.
16
Pull
out
the red Emergency Stop button to the on position
and push the lower button
on the platform controls
• Result: The
descent alarm should sound.
Emergency Lowering Handle
1030-PA