Page 23
GMG 2646E-OR --- 4646E-OR
Operator’s manual
Series: 2646
E-OR
--- 4646
E-OR
November 2020 #81250.1
4Njƾ7ǍƺNjǍ-LJnjljƾƼǍǂLjLJ'ǁƾƼDŽDžǂnjǍ
The operator conduct a Pre-Start Inspection of the machine before each work shift.
DO NOT
use a damaged or
malfunctioning machine.
Initial
Description
Be sure that the operator’s manual is complete, legible and in the storage container located in the platform.
Be sure that all decals are legible and in place.
Check for hydraulic oil leaks.
Check for battery fluid leaks.
Check the following components or areas for damage, improperly installed or missing parts and unauthorized modifications:
Electrical components, wiring and electrical cables
Battery connections
Electrical components, wiring and electrical cables
Battery pack and connections
Drive motors
Slide blocks/wear pads
Tires and wheels
Ground strap
Limit switches, alarm and beacon
Nuts, bolts and other fasteners
Platform entry gate
Beacons and alarms
Maintenance Lock
Platform extension
Scissor pins and retaining fasteners
Platform control handle
Brake release components
Pothole guards
Check entire machine for:
Cracks in welds or structural components
Dents or damage to machine
Be sure that all structural and other critical components are present and all associated fasteners and pins are
in place and properly tightened
Be sure that guard rails are properly installed and secured, and that all pins
and bolts are properly fastened.
Be sure that the chassis trays are closed and latched and
the batteries are properly connected.
NEVER perform work or inspection on the machine with the platform elevated without
first blocking the scissor assembly with the Maintenance Lock.