Page 4
www.GoGMG.com
)DžƾƼǍNjLjƼǎǍǂLjLJ,ƺǓƺNjƽ
ELECTROCUTION HAZARD! THIS MACHINE IS NOT INSULATED!
DEATH OR SERIOUS INJURY will result from contact with or inadequate
clearance from any electrically charged conductor.
You must maintain a CLEARANCE OF AT LEAST 3.05 m between any part of
the machine, or its load, and any electrical line or apparatus carrying over 300
Volts up to 50,000 Volts. 30.5 cm additional clearance is required for every ad-
ditional 30,000 Volts.
Observe Minimum Safe Approach Distance.
This machine is not electrically insulated and will not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines and apparatus in accordance with
applicable government regulations and the following chart:
Minimum safe distance voltage conductors
Voltage
0 to 300 Volts
Avoid contact
Over 300V to 50kV
3,10 m
Over 50kV to 200kV
4,60 m
Over 200kV to 350 kV
6,10 m
Over 350kV to 500kV
7,60 m
Over 500kV to 750 kV
10,7 m
Over 750kV to 1000kV
13,7 m
Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.
Keep away from the machine if it contacts energized power lines. Personnel on the ground or
in the platform must not touch or operate the machine until energized power lines are shut off.
Do not use the machine as a ground for welding.
DO NOT touch the machine if it contacts energized power lines
Personnel in the platform:
•
Move away from the platform rails
•
DO NOT attempt to operate the machine
•
DO NOT touch any part of the machine until energized power lines are shut off.
Personnel in the ground:
•
DO NOT approach the machine
•
DO NOT touch or operate the machine until energized power lines are shut off.
Do not operate the machine during electrical storms or lightning
13302
13303
,E^EVHW
Summary of Contents for 2646E-OR
Page 39: ...www GoGMG com Page 36 2...