CONTROL PANEL
A. "LCD"(Display)
To display the setting values in the laminator.
When the Power is ON, LCD is lighted on.
Refer to the "Explanation of Display" for each displays.
B. "MASTER DIAL"
Dial to adjust values of Roller Temp.(C), Paper Length(D), Laminating Speed(E), Job Mode(F), Bursting Point(G), etc.
☞ How to use of MASTER DIAL
1. Press a button to adjust a required value.
2. Turn "MASTER DIAL" to left / right to set up for required setting value.
Turn "MASTER DIAL" to right to increase the value and turn it to left to decrease the value.
☞ Other Functions of MASTER DIAL
1. While the "MASTER DIAL" is pressed, the current temp. is displayed.
2. Press SPEED button and MASTER DIAL at the same time, it makes COUNTER RESET.
3. Press STOP button and MASTER DIAL at the same time for 5 secs. to change the mode to AUTO or to MANUAL.
NOTE
: AUTO MODE is to integrated with GMP Automatic Feeder of PROFEEDR-5478. (Contact GMP to purchase it.)
C. "TEMP"(Button to set up the Roller Temp.) :
To set up the Roller Temp. Temp. Setting Range is "0 ~ 150"℃ .
☞ How to set up the MIRROR Roller Temp.
:
Press "TEMP" button to "ON" and set up a required temp. with "MASTER DIAL".
☞ How to set up the Embossing Roller Temp. :
In normal status (SINGLE MODE), no power is supplied to the Embossing Roller Heater.
To heat up the Embossing Roller, change the mode to DUAL MODE.
1. Press "JOB" button for more than 3 secs. to change it to "DUAL" mode.
2. Press "TEMP" button to "OFF" and set up a required temp with "MASTER DIAL".
The set up value is saved automatically after 5 secs.
CONTROL PANEL
14/51