HOW TO USE CONTROL PANEL
② "T: 000℃ / 029℃" "B: 000℃ / 018℃" - for display of Temp. & Jobs
To display Setting / Current Temp. of Laminating Roller and Job Availability. Setting Temp. Range is "0~150℃".
'000' is Setting Temperature. '029' is Measure Temperature.
If the both temperature will becomes same, you can start lamination work.
NOTE : Refer to "Buttons" functionality for how to set temp.
③ "BURST" - for display of substrate cutting size
To display operation time for bursting roller. Setting Bursting Point Range is Min. "960"~ Max. "1060".
Recommendable Setting Value is 1000.
NOTE : Refer to "Buttons" functionality for how to set bursting time.
④ "SPEED" - for display of roller speed
To display rotation speed of laminating roller. Speed setting range is Min. "1" ~ Max. "15".
NOTE : Start at low speed for initial stage of job.
⑤ "LENGTH" - for display of substrate length
Displayed value means substrate length. Setting value of substrate length is a required length for lamination.
Setting substrate length range is 250~800mm.
참고 : Refer to "Buttons" functionality for how to set substrate length.
⑥ "FWD OFF" - for display of status for LAMINATOR MAIN MOTOR.
- FWD OFF : Forward Operation is stopped.
- FWD ON : Forward Operation is being processed.
⑦ "C:00055" - for display of daily lamination q'ty
To display q'ty of laminated results for a certain period. It can be reset if it is required.
NOTE : Refer to "Button" functionality for how to reset counter.