Problem
Probable cause
Solution
The compressor motor does
not connect when reaching
minimum pressure.
Damaged pressostat.
Make the substitution of the
pressostat.
There is pressure fall in the
reservatory.
Connections leaking.
Generally this happens all
along of the air line between
compressor and the equip-
ment and not in the connec-
tions of the compressor. Fill
the air compressor the máxi-
mum possible and with help
of a sponge and detergent,
apply a bit of foam on the
connections, observe were
are the leakages and remake
the connection.
The compressor motor or the
power cable presents super
heating.
Electric net underdimen sio-
ned (wire with gauge smaller
than recommended).
The electric net should
be in conformity with the
specifications described in
the manual.
Air loss by the solenoid valve
with the compressor sto-
pped.
Retention valve damaged or
with residues interfe ring in
its normal operation.
Unload the air contained in
the reservoir, remove the re-
tention valve, disassemble it
and verify if the valve is da-
maged. If yes, change it, if
no, make its cleaning.
Air loss by the valve sole-
noid with the compressor in
operation.
Solenoid valve damaged or
with residues interfering in
it’s normal operation.
Unload the air contained in
the reservoir, remove the
solenoid valve, disassemble
it and verify if the valve is
damaged. If yes, change it, if
not, make its cleaning.
The compressor emits exces-
sive noise with metallic and
ritmic blows.
Bloqued bearing or motor
excentric is loose of central
shaft.
Make substitution of motor.
Note: the head of the motor
shall be sent to factory.