6
Characteristic and operation
01 Electric Motor (head)
Responsible for the capitation of the external air directing the same to the interior
of the reservoir.
02
Air input filter
It serves to filter the air that is sucked of the external ambient and led until the
reservoir.
In no hypothesis the compressor should work without this device, because this
guarantees the air input exempt of impurity to the reservoir.
03 Air input plastic tube
Should be always coupled to the filter of air input (item 02) whose function is to
attenuate the noise caused by air suction.
04 Metallic hose
Built in highly resistant material and flexible, it leads the motor air (head) until the
reservoir.
05 Pressostat
It is a pressure measuring instrument used as system component of equipment
protection. Its basic function is to protect the integrity of the compressor against
overpressure or underpressure applied to the same during your operation.
5a On / Off Key
Located at the top of pressostat, it serves to connect or disconnect the compressor.
06 Air reservoir
Local where the compressed air is deposited.
07 Air reservoir manometer
It indicates the pressure value inside the air reservoir.
08 Safety valve (pressure relief)
They are recommended for use with liquids, compressed air or even some inert gases.
Its function is to go in operation only when there is fault in the pressostat.
In case the pressure inside the reservoir reaches levels above of the maximum
allowed in project, the safety valve opens releasing the air and causing the relief
of the internal pressure.
09 Pressure regulator manometer
It indicates the pressure in the air output
10 Air output slide valve
Responsible for releasing the reservoir compressed air for your use.