background image

10.24 in / 260 mm 
7.09 in / 180 mm
9.72 in / 247 mm 
27
67.25 lbs / 30.5 kg 
Nylon Strap

224 Ah/11.2A; 194 Ah/19.4A; 179 Ah/

35.9A

GP-AGM-224-6V

AGM BATTERY

Quick Start Guide

Length
Width
Height
BCI Group #
Weight
Carrying

WARNINGS

- Risk of fire if battery not installed correctly.
- Use caution with metallic objects near battery terminals.
- Keep terminals protected to prevent accidental shorting.
- Disconnect immediately if battery excessively hot or making hissing sounds.
- Replace any battery that has signs of damage to the terminals, case or cover.
- Do not overcharge or overdischarge battery.

BATTERY SPECIFICATIONS

SPECIFICATIONS

Technology

AGM, VRLA deep cycle battery

Nominal Voltage

6 V

Rated Capacity
77°F (25 ±5 °C)

Capacity Correction for

 

Temperature Variations

104°F (40°C) 103%

77°F (25°C) 100%

32°F (0°C) 86%

Maximum Discharge

Current

Specific Energy Density
Volumetric Energy Density
Internal Resistance 

Approx. 1.4mΩ

Terminals 

T11

Torque: 11 ~ 14.7 Nm (97.28 - 130 in*lbs)
100% Depth of Discharge ~ 250 cycles

50% Depth of Discharge ~ 1100 cycles

30% Depth of Discharge ~ 2250 cycles

UL; CE; IEC60896-21 & 22

Cycle Life

77°F (25°C)

Temperature Range

Certifications

Charge:         0~40°C (32~104°F)
Discharge:  -15~50°C (5~122°F)
Storage:       -15~40°C (5~104°F)

Self Discharge 

Batteries can be stored for up to 6 months 

before a freshening charge is required.

*Batteries stored at temperatures

greater than 77°F (25°C) will require a

recharge sooner.

Cycle Use

Cold Cranking Amps (CCA)

900

Initial Charging Current less than 30.0 A

Voltage: 7.2 V~7.4 V at 77°F (25°C)

Temp. Coefficient -30mV/°C 

Standby Use

No limit on Initial Charging Current

Voltage: 6.8 V~6.9 V at 77°F (25°C)

Temp. Coefficient -20mV/°C

2000 A (5s)

116.27 Wh/L

44.07 Wh/kg

Find tech tips, manuals and support at gpelectric.com