background image

MODIFIED SINE WAVE 

INVERTER         

GP-225/400/800/1000HD

User Manual

© 2016 Go Power!

®

Worldwide Technical Support and Product Information 

gpelectric.com

Go Power! Corporate Headquarters

250 Bay St, Victoria, BC Canada V9A 3K5
Tel: 1.866.247.6527

80690_MANUAL_GP-225-400-800-1000-HD_RevA

Summary of Contents for GP-1000HD

Page 1: ...00 800 1000HD User Manual 2016 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Corporate Headquarters 250 Bay St Victoria BC Canada V9A 3K5 Tel 1 866 247 6527 8069...

Page 2: ...4 5 GP 400 800 1000HD INSTALLATION AND TESTING 19 4 6 BATTERY PRECAUTIONS 21 4 7 DC WIRING SIZING 22 4 8 DC GROUNDING 23 5 OPERATION 24 5 1 OPERATING PRECAUTIONS 24 5 2 CONNECTING AC LOADS 25 5 3 CON...

Page 3: ...national electrical codes These instructions are for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical powe...

Page 4: ...rs to be damaged in any way See the Warranty section for instructions on returning the equipment WARNING Hazard to Human Life This type of notation indicates that the hazard could be harmful to human...

Page 5: ...k and utility grid components If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired People with pacemakers should consult thei...

Page 6: ...NING Fire Hazard Do not keep combustible or flammable materials in the same room with the equipment Some products contain relays with moving parts and are not ignition protected Ensure AC DC and groun...

Page 7: ...smoke or allow a spark or flame near the batteries Always use insulated tools Avoid dropping tools onto batteries or other electrical parts Never charge a frozen battery Never use old or untested bat...

Page 8: ...s If battery acid contacts skin or clothing wash immediately with soap and water If acid enters the eye immediately flood it with running cold water for at least 20 minutes and get medical attention a...

Page 9: ...ect reliable or current The specifications in this manual are for reference purposes only and are subject to change without notice For additional information please see www gpelectric com DISCLAIMER G...

Page 10: ...FINISH X XX XXX XXXX 1 01 005 0005 63 I THIRD ANGLE PRO DOC 57012 B DOC REVISION OCESSES TO BE ROHS COMPLIANT CERTIFICATE REQUIRED WITH INITIAL SHIPMENT NOTES 1 TYPE YOUR NOTES IN HERE 2 FEEL FREE TO...

Page 11: ...84 SHEET SIZE REVISION SCALE DRAWING NO CAD REFERENCE Carmanah Technologies Corp 250 Bay Street Victoria BC Canada V9A 3K5 Tel 250 380 0052 Fax 250 380 0062 CHANGES SHALL BE INCORPORATED ELECTRONICALL...

Page 12: ...ircuit Protection System Shutdown USB Output Voltage 4 75 5 25 VDC 2 1 A Output Waveform Modified Sine Wave AC Output Connections 2 Standard North American Outlets USB Connections 1 USB Ports Protecti...

Page 13: ...ircuit Protection System Shutdown USB Output Voltage 4 75 5 25 VDC 2 1 A Output Waveform Modified Sine Wave AC Output Connections 2 Standard North American Outlets USB Connections 1 USB Ports Protecti...

Page 14: ...n USB Output Voltage 4 75 5 25 VDC 2 1 A Output Waveform Modified Sine Wave AC Output Connections 2 Standard North American Outlets USB Connections 1 USB Ports Signal and Control Remote Controller Pan...

Page 15: ...wn USB Output Voltage 4 75 5 25 VDC 2 1 A Output Waveform Modified Sine Wave AC Output Connections 2 Standard North American Outlets USB Connections 1 USB Ports Signal and Control Remote Controller Pa...

Page 16: ...rranty 6 Do not use in a marine application This Inverter is not intended to withstand the highly corrosive conditions in marine applications and would quickly be rendered inoperable or unsafe 7 Keep...

Page 17: ...down if its internal temperature gets too high Note even though this Inverter has built in mechanisms to minimize damage these situations should be avoided because they can still damage the Inverter...

Page 18: ...use rating of your lighter It is recommended that you DO NOT exceed the load capability your vehicles electrical system or modify the size of the fuses installed by the manufacturer 1 Unpack and inspe...

Page 19: ...nverter Remember the terminal is positive and the terminal is negative Place the lug connector between the washers and tighten the terminal screw or nut to clamp the wires securely Ensure connections...

Page 20: ...the presence of flammable fumes as explosion or fire may result 8 Set the power switch to the ON position Check the meters and indicators on the front panel of the Inverter The Function LEDs should be...

Page 21: ...he other cable 7 Install a properly rated fuse on the positive output of the battery bank The following points must be observed for the DC Wiring The DC positive and negative cables connected to the I...

Page 22: ...added together should be less than 10 ft 3 m to comply with code requirements Keeping your wire runs as short as possible helps to prevent low voltage shutdowns and nuisance tripping of the DC breaker...

Page 23: ...unding system is sometimes referred to as the Earth ground or another designated ground For example on an RV the metal frame of the RV is designated as the negative DC ground RV ground The DC ground w...

Page 24: ...other condition that may affect the Inverter s operation If damaged have it repaired before use 6 Do not attempt to power a device or combination of devices that will require more than the rated outp...

Page 25: ...he point that it will no longer start the engine If needed operate the engine periodically to maintain the batteries charge Do not operate a vehicle s engine in an enclosed space 5 3 CONTROLS AND INDI...

Page 26: ...r refuses to start observe the battery voltage indicator while trying to start the motor If the battery voltage indicator drops below 11 V while the Inverter is attempting to start the motor this may...

Page 27: ...talled in a location that does not allow it to dissipate heat properly The power inverter will restart automatically once it has cooled off 5 8 OVERLOAD The fault LED will come on when the Inverter ha...

Page 28: ...or replace battery 5 Clean and tighten connection 6 Remove charging source and make sure correct battery is being used and connected correctly Output voltage is incorrect Input voltage is too high or...

Page 29: ...erson using only identical replace ments This will ensure that the safety of the Inverter is maintained 4 Fuses must be replaced with fuses of the same type and rating only 7 2 MAINTENANCE Very little...

Page 30: ...tion of our website to troubleshoot the problem If trouble persists 1 Call your Go Power Technical Support team 1 866 247 6527 or 2 Return defective product to place of purchase Unless approved by Go...

Page 31: ...nowing for sure if your appliances are being recycled properly is tricky If you re in doubt just ask Recyclers that are certified should gladly show you their certification If the re cycler is certifi...

Page 32: ...Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Corporate Headquarters 250 Bay St Victoria BC Canada V9A 3K5 Tel 1 866 247 6527 80690_MANUAL_GP 225 400 800 1000 HD...

Reviews: