hOw TO CLEAN ThE hEPA fILTER
It is very important to keep the filters clean to receive maximum performance from the vacuum.
Clean the filter regularly and replace the filters when necessary.
HEPA Dust Cup Filter will stop most of the tiniest dust particles and airborne allergens from
reentering the air you breathe. In fact it stops 99.97% of all particles as small as 0.3 microns-
many times smaller thana human hair! Because of this incredible filtration performance, the
HEPA Filter will quickly accumulate may fine dust particles inside the white filter folds that are
difficult to see but which will eventually block or reduce your suction power, if not cleaned prope
-
rly. We recommend washing it once a month or when suction appears to be reduced. To wash
your HEPA Filter, hold filter cartridge by frame flange and rinse under a tap until all observable
dirt has been removed. Some discoloration of the HEPA filter material may occur, this is normal
and will not affect the filter‘s performance. When finished, shake off excess water.
Do NOT wash in dishwasher. It is important that when you wash the HEPA filter, you allow it to
dry COMPLETELY before using again. We recommend 24 hours to air dry. DO NOT DRY IN
DRYER.
The HEPA filter operating lifetime corresponds to about 10 to 15 washing cycles. After that, the
filter looses its performance and it should be replaced.
Caution!
Only ever clean the filter with clean water and do not use soap or detergent. These would
destroy the filter.
TROUbLE-ShOOTINg
Faults can occur on all electrical equipment. This must not necessarily be due to a defect in the
device itself. So check first with table if the fault can be dealt with.
PRObLEM
POSSIbLE CAUSES
SOLUTIONS / TIPS
Weak suction
The secondary valve is open. Close the secondary valve
An object is blocking the sucti
-
on pipe
Check the suction tube, the
handle area, suction pipe and
the nozzle in use for blockages.
Filters are not fitted properly
or are blocked
Fit a new filter
Device does not work.
Device is not properly plugged
into the mains
Check that the mains plug
has been inserted properly.
Also check whether the power
socket is in order (e.g. use
an electric torch). Check the
fusels! Automatic fuses in the
fuse box
Thermostat automatic turned
off the unit
Follow instructions on page 26,
section Motor thermostat
Don´t close front cover
Isn´t the filter bag placed in
the body. Isn´t the sitting cor
-
rected
Please replace correctly the
filter bag
The cord can not be retrated Isn´t the core tangled?
After unfastening tangled cord.
Pull out the by 1 or 2 meter and
push button to wind it again.