30
Please perform the following procedure:
Picture 1 & 2: Check the alignment of the application head (A) and the printer peeler edge (B).
• The horizontal distance between applicator head and peeler edge (1) must be 0,5mm to 1mm.
• The applicator head and the peeler edge must be aligned perfectly parallel to each other
• The bottom of the applicator head should be the same height (2) as the upper end of the peeler
edge.
• If the height has been set correctly the label will slightly bend down to move forward under the
head (3)