37
©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the
right to amend specifications without notice or obligation.
OPEN and CLOSE LEDs
The OPEN (or CLOSE) LED will light while the OPEN (or CLOSE) button is pressed.
These LEDs will normally be off.
Valve position bargraph indicator (LEDs)
The valve position bargraph indicates the relative position of the valve in reference to
the WET (open) and DRY (closed) presets. Fully WET (open) will light all six (6) bars
and fully DRY (closed) will light only the bottom bar.
Note:
turning off the FoamLogix or disengaging the compressor will send the Air Ratio
Control valve to the extreme WET position.
Operating the PC2_ or PC1_ from a Vehicle Water Source
1. Delivery Hose
Connect a suitable delivery hose and branch to the CAFS discharge.
38 to
45mm
diameter lay flat hose is suitable for delivering compressed air foam.
2. Nozzles
If a single discharge is used -
For both Prima SmartCAFS50 and 100 a
25 to
38mm smooth bore nozzle is
suitable.
If two delivery hoses are used -
For Prima SmartCAFS50
– 2 x
19mm nozzles are suitable.
For Prima SmartCAFS100
– 2 x
25mm nozzles are suitable.
Note:
Superior foam quality is produced using a smooth bore nozzle and a delivery
system with the least amount of valves and sharp bends. However, the scrubbing
action of the foam on the hose wall tends to improve the foam quality.