43
©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the
right to amend specifications without notice or obligation.
MAINTENANCE OPERATIONS PC1_ / PC2_
CAFS Mixing Manifold
– Greasing Ball Valve
The CAFS Mixing Manifold contains a ball valve as part of the air ratio control system.
This ball valve must be maintained by inserting lubricating grease at three monthly
intervals to ensure smooth and efficient operation.
Use a marine waterpro
of grease, e.g “Aquaslip” (supplied by Tetrosyl Ltd., Bury,
Lancashire, BL9 6RE. www.tetrosyl.com)
Ball Valves without remote grease lines
On early models of the CAFS mixing manifold the grease is inserted through one or two
grease nipples. The first nipple is located on the side of the valve facing the rear of the
pump. If a second nipple is fitted, it will be on the side of the manifold facing the
compressor. Connect a suitable grease gun to the nipples and insert grease until a
resistance is felt, this indicates that sufficient grease has been inserted.
Ball Valves with remote greasing lines
On later models the CAFS mixing manifold is fitted with two grease lines, these allow
grease to be inserted from the front panel.