background image

Godrej & Boyce Mfg. Co. Ltd, HO Service, Mumbai   

 

 

 

   SM 3202 - Page 21 of 23 

 

 
 
 
 

Summary of Contents for GSC 18 FV 5 HRML

Page 1: ...ion CUSTOMER SERVICE PLANT 11 PIROJSHA NAGAR VIKHROLI MUMBAI 400079 Prepared by Larkins D souza Authorized Issued by S A Jamadar For private circulation only Rs 250 SERVICE MANUAL For Godrej Air Condi...

Page 2: ...Personnel 3 3 Safety Precautions 4 4 Good Servicing practices 5 5 Nomenclature 6 6 Specification for GSC 18 FV 5 HRML 7 7 Exploded View Indoor GSC 18 FV 5 HRML 8 8 Exploded View Outdoor GSC 18 FV 5 H...

Page 3: ...l engaged in providing efficient service to valued customers We certainly referred to many books journals and other documents to enable us to provide you updated information An inexperienced and unaut...

Page 4: ...highly trained and competent Repairing the air conditioner right the first time Showing respect to customer the air conditioner and the home Using neat work habits and carefully cleaning up after the...

Page 5: ...ents 6 Never interfere with or bypass the operation of any switch component or feature of the air conditioner 7 Use only replacement parts of the same size and capacity as per the list of parts If you...

Page 6: ...components of the system 7 Using 2 stage rotary vacuum pump for evacuation of tubes and sealed system 8 Minimize brazed joints and making proper joints Flare joints 9 Flushing with dry Nitrogen gas 10...

Page 7: ...9 k Btu 21 k Btu 24 k Btu G Grille F Flat C Cooling H Heating Cooling G S C 18 F V 5 H R M L Color Finish White Red Aurica Silver Gold Black Mirror etc Year of Launch Base A 2001 M 2013 Version V Vogu...

Page 8: ...tor Model MP24AA Rating V DC 12 Other Details Sound Level dB A H M L 46 42 38 Dimension W D H mm 940 X 200 X 298 Net Weight kg 13 Outdoor unit Compressor Compressor Model No Highly SH295RY C7PUA Compr...

Page 9: ...Godrej Boyce Mfg Co Ltd HO Service Mumbai SM 3202 Page 8 of 23 Exploded View GSC 18 FV 5 HRML Indoor Unit...

Page 10: ...Only 1 Front Panel AGRSHV518F2 2 Filter Sub assy AFLSHV518FA 3 Rear Panel AGRSHV518RP 4 Screw Cover AMSSHV512SC 5 Display PCB ACCSHV518DP 6 Evaporator Assy AEVSHV518EA 7 LH Evaporator Support ABKSHV51...

Page 11: ...e AMSSHV518HT 14 Swing Louver RH ALVSHV518VR 15 Left Axile Bush AMS97740349 16 Axile Bush AMS97740399 17 Swing Louver Horizontal Silver ALVSHV518HL 18 Louver link AMS97740400 19 Swing Motor AMT9774045...

Page 12: ...For Reference Only 26 Electric Box AMSS24D2ELB 27 Main PCB ACCSHV518MP 28 Transformer AFN97740458 29 IDU Terminal Block AMS97740460 30 Electric Box Cover1 AMSS24D2BC1 31 Shield cover of Electric Box...

Page 13: ...n Codes Image For Reference Only 35 Ambient Temperature Sensor AMS97740466 36 Remote Controller ACC97740356 37 Connecting Cable AMSS18D3CNC 38 Power Cord AICSHV518PC 39 Drain Stopper AMSS10D3DRS Shiel...

Page 14: ...Godrej Boyce Mfg Co Ltd HO Service Mumbai SM 3202 Page 13 of 23 Exploded View GSC 18 FV 5 HRML Outdoor Unit...

Page 15: ...ML Ref Part Name Item Code Image For Reference only 1 Air Outlet Grill AGRSLJ218DG 2 Front Panel AMSSLZ518FP 3 Condenser Fan AFBSLZ518FB 4 Fan Motor AMTSLZ518FM 5 Support Motor ABKSLJ218MS 6 Compresso...

Page 16: ...e For Reference only 10 Partition Panel AMSSLJ218PP 11 Interconnecting Cable AMSSLJ218CC 12 Suction Valve AVLSLJ218SV 13 Liquid Valve AVLSLJ218LV 16 Top Cover AMSSLJ218TC 17 Base Pan ABSSLZ518BS 18 Co...

Page 17: ...e Item Code Image For Reference only Poly Bag APASLJ218PB Corrugated Base Tray APASLJ218CB Angle Board AMSSLJ218AB 21 Metal Control Box ACCSLJ218CB 22 Compressor Capacitor ACPSLZ518CC 23 Fan Motor Cap...

Page 18: ...Godrej Boyce Mfg Co Ltd HO Service Mumbai SM 3202 Page 17 of 23 Model GSC 18 FV 5 HRML Schematic Wiring Diagram IDU Schematic Wiring Diagram ODU...

Page 19: ...ess the Clock key 12 00 is the default setting LIGHT button Press this button to select LIGHT on or off on the displayer When the LIGHT on is set the icon will be displayed and the indicator light in...

Page 20: ...e current display status on the indoor unit will remain unchanged If current display is indoor ambient temperature and another signal is received from the hand set the display will change to the prese...

Page 21: ...Godrej Boyce Mfg Co Ltd HO Service Mumbai SM 3202 Page 20 of 23 Trouble Shooting...

Page 22: ...Godrej Boyce Mfg Co Ltd HO Service Mumbai SM 3202 Page 21 of 23...

Page 23: ...Godrej Boyce Mfg Co Ltd HO Service Mumbai SM 3202 Page 22 of 23...

Page 24: ...ode Conflict E7 Compressor overload protection H3 Anti Hi Temp Protection E8 System abnormal H4 Anti Cold Wind Protection E9 Module protection H5 Lower running frequency due Low Voltage of Power Suppl...

Reviews: