16
RELAY CONTROL SYSTEM ELECTRICAL INSTRUCTIONS
Route the cable through one of the station knockouts and carefully reinstall the cover. Make
sure that the cover is installed properly and that the buttons work freely.
The other end of the 5-
conductor “Thermo
-
Wire” is attached to the control terminals at the external
operator. The blue (Open) wire connects to the same terminal as the blue wire from the primary control
station (Terminal #7). The white (Close) wire will connect to Terminal #6, and the green wire (Common)
connects to Terminal #8.
In order to connect the Stop buttons in series, disconnect the red wire from the primary control station
from Terminal #9. Use the included blue wire nut to fasten it to the yellow wire of the station that you
are adding (5-conductor bundle). Connect the red wire for the new station to Terminal #9. Your
connections should resemble the following photo.