Leak detector type LAG 2000 A
26 / 28
part no. 15 071 53 e
TECHNICAL DATA
Display unit and/or 2nd display unit
supply voltage
230VAC 50 - 60Hz ± 10% to 15%
relay output 1 potential-free
relay contact
max.
switched voltage
250VAC (50 - 60)Hz
max.
switched
current 1
.
0A
max. switched
power
100VA
safe electric circuit
U
o
= 19
.
6V I
o
= 7
.
62mA P
o
= 37
.
3mW
sound level alarm sound
min. 70dB(A)
ambient temp.
T
amb
-5°C to +50°C
protection type
IP20 acc. EN 60529
power consumption P
max. 3
.
6W
dimensions
120 x 120 x 50mm
housing material
PS
marking ignition protection type
II (1) G [Ex ia] IIC
EU-declaration of type approval EPS 16 ATEX 1 171
electrical device acc.
EN 60335-1
•
over-voltage caterogy III
•
contamination degree 2
•
protection class type I
Technical data for LDL tank and sensor unit
material
PE electrostatically conductive
marking ignition protection type
Ex II 1 G Ex ia IIC Ga
EU-declaration of type approval EPS 16 ATEX 1 172 U
safe electric circuite
U
i
= 25V
I
i
= 40mA
P
i
= 270mW
nominal volume V
N
10
.
4L
usable Volume V
a
4
.
5L
connection Connection line
male thread G 3/4 A
with double sleeve
both sides female thread G 3/4
installation direction
vertical
length of sensor cable
0
.
5m
permissible ambient
temperature
T
amb
-20°C to +60°C
permissible temp. of operating
medium
T
lig
-20°C to +60°C
ambient pressure p
amb
abs.
0
.
08MPa (0
.
8bar) to 0
.
11MPa (1
.
1bar)