737 MAX Flight Crew Operations Manual
Normal Procedures -
Amplified Procedures
MN-FLT-OH-201
NP.21.25
MAX8 Fleet Only
Display Select panel....................................................................... Set
Display Selector switch - PFD/MFD NORMAL
GROUND PROXIMITY panel ................................................ Check
FLAP INHIBIT switch - Guard Closed
GEAR INHIBIT switch - Guard Closed
TERRAIN INHIBIT switch (as installed) - Guard Closed
Verify that the GROUND PROXIMITY INOP light is
extinguished.
Landing gear panel ........................................................................ Set
LANDING GEAR lever - Down
Verify that the green landing gear indicator lights are illuminated.
Verify that the red landing gear indicator lights are extinguished.
MAX8 Fleet Only
NOSE WHEEL STEER switch..................................... Guard Closed
MAX8 Fleet Only
FUEL FLOW switch ................................................................... Rate
Move switch to RESET then RATE.
MAX8 Fleet Only
Left SELECTOR switch ..................................................................C
MAX8 Fleet Only
Hydraulic brake pressure indicator .......................................... Check
Note:
check pressure in amber or green band. Indication within
amber band is normal with hydraulic system “B” not
pressurized.
-700 and -800 Fleets Only
Engine display control panel ......................................................... Set
N1 SET selector ................................................................. AUTO
SPEED REFERENCE selector .......................................... AUTO
MAX8 Fleet Only
ENG TRF ....................................................................................... Set
Set engine indications on captains side.
March 1, 2021