737 MAX Flight Crew Operations Manual
Supplementary Procedures -
Flight Instruments, Displays
MN-FLT-OH-201
SP.10.3
Setting Airspeed Bugs with No Operative FMC
(Manual Airspeed Bug Setting)
To set reference airspeed bugs for takeoff:
Speed reference selector (outer) ................................................V1
Default speed of 80 knots is displayed.
Speed reference selector (inner) ............................... Set V1 speed
V1 bug is displayed when a speed greater than 80 knots is set.
The NO VSPD flag is displayed until both V1 and VR are set.
Speed reference selector (outer) ...............................................VR
Default speed of 80 knots is displayed.
Speed reference selector (inner) ...............................Set VR speed
VR bug is displayed when a speed greater than 80 knots is set.
The NO VSPD flag is removed after both V1 and VR are set.
MCP speed selector ............................................................Set V2
Airspeed cursor and V2+15 bug move to the correct speeds.
Speed reference selector (outer) .............................................. WT
YA201 - YT705, YV401 - YV671
Default weight of 32,000 kgs is displayed.
Speed reference selector (inner) ..............Set takeoff gross weight
Flaps up maneuver speed bug is displayed.
Note:
If VREF is selected on the ground, INVALID ENTRY is
displayed.
To set the spare bug, if desired:
Speed Reference selector (outer) ...........................Spare bug
Default speed of 60 knots is displayed.
Speed reference selector (inner) ........................................Set
Set speed as desired.
Speed reference selector (outer) ............................................. SET
Digital readout is removed.
March 1, 2021